Samlexpower SMC-20 Owner's Manual - Section 6 |
SAMLEX AMERICA INC. | 13
SECTION 6 |
Troubleshooting
ISSUE
CAUSE
REMEDY
LOAD CANNOT
BE OPERATED
+
INFO LED (1)
FLASHES RED
+
GREEN LED (2d)
FLASHES
Load output is switched
OFF due to excessive
battery voltage
The load output automatically
switched on again as soon as the
battery voltage lies within the
permissible range
Incorrect grounding
Check the grounding. Grounding
is allowed only on the Negative
Battery Terminal
External charging source
is not voltage-limited
- Check the external charging
source
- If necessary, switch OFF external
charging source
LOAD CANNOT
BE OPERATED
+
INFO LED (1)
ILLUMINATES
GREEN
Defective load or
installation error
- Connect load correctly
- Replace load
BATTERY IS
NOT CHARGED
Solar module not
connected
Connect the solar module
Solar module
connected with
incorrect polarity
Connect the solar module with
the correct polarity
Short circuit at solar
module input
Correct the cause of the short
circuit
Incorrect solar module
voltage
Use a solar module of the
specified voltage
Solar module defective
Replace the solar module
BATTERY DISPLAY
JUMPS QUICKLY
Large pulse current
Adjust the current consumption
to match the battery capacity
Battery is defective
Replace the battery