Load cannot be
operated
+
info LED flashes
red
+
red battery LED
flashes
Load output is switched
off due to too low battery
voltage
•
The load output automati-
cally switched on again as
soon as the battery voltage
lies within the permissible
range
Pre-charge the battery
Equip loads directly con-
nected to the battery with
deep discharge protection
Check the battery and
replace if necessary
Load cannot be
operated
+
info LED flashes
red
+
. green LED
flashes
Load output is switched
off due to excessive battery
voltage
•
The load output automati-
cally switched on again as
soon as the battery voltage
lies within the permissible
range
External charging source is
not voltage-limited
•
Check the external charging
source
If necessary, switch off
external charging sources
Load cannot be
operated
+
info LED illumi-
nates green
Defective load or installa-
tion error
•
Connect load correctly
Replace load
Battery is not
charged
Solar module not connected
•
Connect the solar module
Solar module connected
with incorrect polarity
•
Connect the solar module
with the correct polarity
Short circuit at solar module
input
•
Correct the cause of the
short circuit
Incorrect solar module
voltage
•
Use a solar module of the
specified voltage
Device overheated
•
Make sure the device is well
ventilated
Solar module defective
•
Replace the solar module
Battery display
jumps quickly
Large pulse current
•
Tune the current consump-
tion to match the battery
capacity
Battery is defective
•
Replace the battery