Samplex America Solarix MPPT 2010 Installation And Operating Instructions Manual - 3.3 Leddisplays
7
730.97 | 09.10
3.3 LEDdisplays
LED
Status
Meaning
Info LED
illuminates
green
normal operation
flashes red
a fault exists (see "Faults and remedies")
Red LED
flashes quickly battery empty
when the battery continues to be discharged
the deep-discharge deactivation is triggered
flashes
deep-discharge deactivation
Yellow LED
illuminates
battery weak
flashes
switch-on threshold after deep-discharge deacti-
vation has not yet been reached
1. green LED illuminates
battery good
. green LED illuminates
battery full
flashes quickly battery full, charge regulation active,
i.e. charging current reduced
4. Installation
WARNING
Dangerofexplosionfromsparking!Dangerofelectricshock!
Solar modules generate electricity under incident light. The full voltage is
present, even when the incident light levels are low.
The solar charge controller may only be connected to the local loads and the
battery by trained personnel and in accordance with the applicable regulations.
Follow the installation and operating instructions for all components of the
PV system.
Ensure that no cables are damaged.
At a voltage of > 75 V, particularly with regard to module open circuit volt-
age (over the entire temperature range), the entire solar energy system must
be installed with protection class II.
Protect the solar modules from incident light during installation, e.g. cover
them.
Never touch uninsulated cable ends.
Use only insulated tools.
Ensure that all loads to be connected are switched off. If necessary, remove
the fuse.
Connections must always be made in the sequence described below (see
4..).