Samplex America Solarix MPPT 2010 Installation And Operating Instructions Manual - Technicaldata
16
730.97 | 09.10
8.
Technicaldata
MPPT2010
Characterisationoftheoperatingbehaviour
System voltage
1 V (4 V)
Rated output
50 W (500 W)
Max. efficiency
> 98 %
Own consumption
10 mA
DCinputside
MPP voltage
15 V (30 V) < U
module
<< 100 V
Open circuit voltage solar module
(at minimum operating temperature)
**17 V ... 100 V (34 V ... 100 V)
Module current
18 A
DCoutputside
Charging current
0 A
Load current
10 A
End-of-charge voltage*
13.9 V (7.8 V)
Boost charge voltage*
14.4 V (8.8 V)
Equalisation charging*
14.7 V (9.4 V)
Reset voltage* (SOC / LVR)
> 50 % / 1.5 V (5.0 V)
Deep discharge protection* (SOC / LVD)
< 30 % / 11.5 V (3.0 V)
Applicationconditions
Ambient temperature
-5 °C … +40 °C
Equipmentanddesign
Terminal clamps (fine-wire / single wire)
16 mm
/ 5 mm
- AWG 6 / 4
Degree of protection
IP 3
Dimensions (X x Y x Z)
187 x 153 x 68 mm
Weight
approx. 900 g
* see options
Technical data at 25 °C / 77 °F
** .
CAUTION
If an open circuit voltage of more than 100 V is supplied to the connected solar
module, the controller will be destroyed. When selecting the solar module, it
is important to bear in mind that the open circuit voltage should never exceed
100 V over the entire working temperature range.
When using solar modules with a maximum open circuit voltage of between
75 and 100 V (over the entire temperature range), all installation steps must be
carried in accordance with protection class II.