Connecting the drain hose to the outdoor unit
When using the air conditioner in the heating mode, ice may accumulate . During de-icing, the condensed water must be
drained off safely. Consequently, you must install a drain hose on the outdoor unit, following the instructions below. (For
AC030-036JXSCCH model, do not install a drain hose and a drain plug.)
1. Provide 3.2 inches minimum between the bottom of the outdoor unit and the ground for installation.
2. Insert the drain plug into the hole on the underside of the outdoor unit.
3. Connect the drain hose to the drain plug.
4. Ensure that the drained water runs off correctly and safely.
3.2 inch
0.51 inch
5. Be sure to plug the rest of drain holes not connected with drain plugs using drain caps.
DRAIN CAP(5EA)
DRAIN PLUG(2EA)
❋ When installing the product, make sure that the rack is not placed under the drain hole.
❋ If the product is installed in a region of heavy snow, allow enough separation distance between the product and the
ground.
• For AC030-036JXSCCH model, do not install a drain hose and a
drain plug.
- Let the water drain naturally.
• Ice may form on the ground. Take appropriate measures to
prevent ice formation.