Step 6 Connecting the refrigerant pipe
◆ AJ040/050MCJ2EH
1
Piping outside diameter.
Indoor unit
Out unit
Power
supply Ø,
V, Hz
Outside
diameter
Liquid Gas
∗∗020/026/
035/07/09/12
∗∗
AJ040MCJ2EH 1,220-240,
50/60
1/4"
3/8"
∗∗
020/023/026
/035/07/09/12
∗∗
AJ050MCJ2EH 1,220-240,
50/60
1/4”
3/8”
∗∗
052/18
∗∗
1/2”
NOTE
• AJ040MCJ2EH Outdoor unit cannot be connected to
the following indoor unit combination.
-NJ∗∗∗ /AJN∗∗/MH052FUEA
•
AJ050MCJ2EH Outdoor unit cannot be connected
to the following indoor unit combination.
-AJN052NDEHA/MH052FUEA
2
Piping length and the height
1 Room
max
length
2 Room
total max
length
Max height
between
indoor unit
& outdoor
unit
Max height
between
indoor units
Dimension
20m
30m
15m
7.5m
Composition
A,B
A+B
(H)
(h)
◆ AJ052/068MCJ3EH
1
Piping outside diameter.
Indoor unit
Out unit
Power
supply Ø,
V, Hz
Outside
diameter
Liquid Gas
∗∗020/023/026
/035/07/09/12∗∗
AJ052MCJ3EH
AJ068MCJ3EH
1,220-240,
50/60
1/4”
3/8”
∗∗052/18∗∗
1/2”
NOTE
• AJ052MCJ3EH Outdoor unit cannot be connected to
the following indoor unit combination.
-AJN052NDEHA/MH052FUEA
2
Piping length and the height.
1 Room max
length
3 Room total
max
length
Max height
between
indoor unit &
outdoor unit
Max height
between
indoor units
Dimension
20m
50m
15m
7.5m
Composition
A,B,C
A+B+C
(H)
(h)
A
B
(h) (H)
Main power switch
Main power switch
A
B
(h) (H)
C
Make at least one round:
It will reduce noise and vibration
Make at least one round:
It will reduce noise and vibration