SeQual Eclipse 2 User Manual

Other manuals for Eclipse 2: Troubleshooting Manual

Summary of Eclipse 2

  • Page 1

    Users manual personal ambulatory oxygen system eclipse ® 2 www.Sequal.Com 800.826.4610

  • Page 3

    Important safety instructions symbols used in users manual and on the eclipse personal ambulatory oxygen system indications for use contraindications safety guidelines oxygen therapy safety operating safety power cartridge safety introduction to your eclipse understanding the controls and front pane...

  • Page 4: And On The Eclipse

    Personal ambulatory oxygen system users manual 4 personal ambulatory oxygen system users manual important safety information for hazards that might cause serious injury. Important safety instructions important safety instructions are shown under the following headings: note: sequal ® technologies in...

  • Page 5: Ipxo

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 5 drip proof equipment-ipx0: the eclipse enclosure does not provide protection against the harmful effects of the ingress of liquids. (ipx0, per iec 60529) drip proof equipment-ipx1: the eclipse ac and dc p...

  • Page 6

    Personal ambulatory oxygen system users manual 6 personal ambulatory oxygen system users manual the eclipse is indicated for the administration of supplemental oxygen. The device is not intended for life support nor does it provide any patient monitor- ing capabilities. Your physician has prescribed...

  • Page 7

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 7 this section of the manual provides warnings and cautions that apply to hazards or unsafe practices that could result in serious injury or property damage. Safety guidelines keep the eclipse and the power...

  • Page 8

    Personal ambulatory oxygen system users manual 8 personal ambulatory oxygen system users manual do not remove the cover. There are no user-serviceable parts inside the device. Only qualified service personnel should remove the cover of the device. Protect electrical power cords from sharp edges. Ele...

  • Page 9

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 9 always disconnect ac power supply from the wall before disconnecting the ac power supply plug from the eclipse. Caution caution caution caution do not short-circuit the power cartridge’s metal contacts wi...

  • Page 10

    Personal ambulatory oxygen system users manual 10 power cartridge safety charging the power cartridge below 50 f° (10° c) or above 104° f (40° c) may degrade the performance of the power cartridge. Warning warning caution caution warning caution caution do not disassemble, puncture, or crush the pow...

  • Page 11: Introduction To Your

    Personal ambulatory oxygen system users manual 11 introduction to your.

  • Page 12

    Personal ambulatory oxygen system users manual 12 personal ambulatory oxygen system users manual this users manual will inform you about the use and care of the eclipse, its standard components and the optional accessories. Please read thoroughly all of the information in this manual before operatin...

  • Page 13: Front

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 13 understanding the controls and front panel description of the eclipse 2 oxygen outlet port air inlet filter service port exhaust vent power cord retainer external power receptacle oxygen supply tubing or...

  • Page 14

    Personal ambulatory oxygen system users manual 14 personal ambulatory oxygen system users manual understanding the controls and front panel (continued) user controls and system status indicators on/off button (green) indicator: this button powers the device on or powers it off. The green indicator i...

  • Page 15

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 15 alarm (red) indicator – high priority alarms: indicates a high priority alarm condition. An immediate response is necessary. Refer to the alerts, alarms, and troubleshooting table and contact your home c...

  • Page 16

    Personal ambulatory oxygen system users manual 16 personal ambulatory oxygen system users manual recommended operating environments operating temperature operating humidity transport/storage temperature altitude placement environment operating time electrical 50º f to 104º f (10º c to 40º c) 10% - 9...

  • Page 17: The Proper Placement

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 17 select a location for the device that avoids the intake of smoke, fumes and pollutants. Correct placement of the device should allow intake of air through the air inlet filter at the back and rear of the...

  • Page 18: Before Operating

    Personal ambulatory oxygen system users manual 18 personal ambulatory oxygen system users manual operating instructions this users manual serves as your reference to help you operate and maintain the device. If you have any questions or concerns please call your home care provider, qualified represe...

  • Page 19: Powering On Your Eclipse

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 19 (1) ac power supply (2) dc power supply (3) rechargeable power cartridge (battery) the eclipse is a lightweight portable and stationary source of supplemental oxygen. The device is capable of being opera...

  • Page 20

    Personal ambulatory oxygen system users manual 20 personal ambulatory oxygen system users manual operating instructions (continued) do not use any power cord if it is damaged or frayed. Improper use of the power cord may result in a fire or electrical shock hazard. Warning warning ac power supply: t...

  • Page 21

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 21 warning warning warning dc power supply: a dc power supply allows the system to operate from dc outlets, such as those found in motor vehicles. You will need to determine the fuse rating in your motor ve...

  • Page 22: Each Fuse Setting

    Personal ambulatory oxygen system users manual 22 personal ambulatory oxygen system users manual operating instructions (continued) device flow settings available for each fuse setting setting continuous pulse continuous pulse 0.5 yes not available yes not available 1.0 yes yes yes yes 1.5 yes yes y...

  • Page 23: Duration-of-Use

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 23 to remove the power cartridge, push up on the release lever on the power cartridge. The power cartridge will slide out as you grasp it for removal. Power cartridge duration-of-use: the duration-of-use of...

  • Page 24

    Personal ambulatory oxygen system users manual 24 personal ambulatory oxygen system users manual operating instructions (continued) caution caution caution caution caution caution u.S. Department of transportation (dot) and united nations (un) regulations require the removal of the power cartridge f...

  • Page 25

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 25 typical power cartridge recharge time the typical time to recharge your power cartridge, in order to achieve 80% capacity, from a fully discharged power cartridge is between 1.4 hours and 5.0 hours, depe...

  • Page 26

    Personal ambulatory oxygen system users manual 26 personal ambulatory oxygen system users manual in the event of an ac power interruption, the eclipse will automatically switch to the power cartridge operation. When ac power is restored, the power cartridge will automatically start recharging. If th...

  • Page 27

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 27 operating your eclipse for the first time step 1: locating your eclipse. Place the eclipse in a well-ventilated area. Be sure the air inlet and exhaust vent are not obstructed. Position the eclipse so th...

  • Page 28

    Personal ambulatory oxygen system users manual 28 personal ambulatory oxygen system users manual operating instructions (continued) step 3: connect the oxygen supply tubing to the oxygen outlet and connect the oxygen cannula per the instructions provid- ed with the cannula, or per the instructions f...

  • Page 29: Pulse Flow Mode And

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 29 warning warning warning pulse setting bolus size max breath per minute (bpm) 1 16 40 2 32 40 3 48 40 4 64 39 5 80 31 6 96 26 pulse setting bolus size max breath per minute (bpm) 1 16 40 2 32 40 3 48 40 4...

  • Page 30

    Personal ambulatory oxygen system users manual 30 personal ambulatory oxygen system users manual step 5: adjust the flow setting to the prescribed level step 6: begin using your eclipse using the flow setting buttons, adjust the flow setting to the prescribed setting sup- plied by your physician. Br...

  • Page 31

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 31 alerts, alarms, and troubleshooting table sh u tdo w n cond it ion s d ev ic e n ee d s a tt ent ion typ ical cond it ion s green indicator yellow indicator red indicator audible alarm what to do conditi...

  • Page 32

    Personal ambulatory oxygen system users manual 32 personal ambulatory oxygen system users manual warning no power cartridge installed install power cartridge or plug into external power power cartridge is discharged or no external power is present plug into external power other contact your dealer/p...

  • Page 33

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 33 eclipse standard components (supplied with each eclipse) warning mobile cart – your eclipse can be easily transported while attached to the mobile cart. The mobile cart has wheels and a telescoping handl...

  • Page 34

    Personal ambulatory oxygen system users manual 34 personal ambulatory oxygen system users manual eclipse optional accessories check with your home care provider,or visit us at www.Sequal.Com for more information about optional accessories. There are many different types of oxygen tubing, cannulae, a...

  • Page 35

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 35 salter labs oxygen cannula, part number 1600 series, or equivalent: your physician will have prescribed a cannula to deliver oxygen. In most cases they are already attached to the oxygen tubing. If not, ...

  • Page 36: Routine Maintenance

    Personal ambulatory oxygen system users manual 36 personal ambulatory oxygen system users manual cleaning, care and routine maintenance servicing of the internal components inside the cabinet of this device must be conducted by a sequal trained and qualified service technician as needed. Your home c...

  • Page 37

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 37 the air inlet filter should be replaced as needed. If the eclipse is used in a dusty environment, the filter may need to be replaced more often. You should not operate the eclipse without an air inlet fi...

  • Page 38

    Personal ambulatory oxygen system users manual 38 personal ambulatory oxygen system users manual the power cartridge (battery) in the eclipse requires special care to assure a longer life and the highest level of performance. The sequal power cartridge is the only approved power cartridge recommende...

  • Page 39

    Personal ambulatory oxygen system users manual personal ambulatory oxygen system users manual 39 manufactured by: sequal technologies inc. 11436 sorrento valley road san diego, ca 92121 usa toll-free: 1-800-826-4610 in the u.S., or 1-858-202-3100 toll-free fax: 877-786-9943 worldwide: www.Sequal.Com...

  • Page 40

    Manufactured by: sequal technologies inc. 11436 sorrento valley road san diego, ca 92121 usa toll-free: 1-800-826-4610 in the u.S., or 1-858-202-3100 toll-free fax: 877-786-9943 worldwide: www.Sequal.Com pn: 4112 rev: a …to outshine and surpass.