3.1.2.4 Sub-Menu TEMPERATURE
This
menu
shows
the
different
temperatures of
the
heating
system.
All
temperature changes registered over
the last 60 minutes are stored in the control system and can be viewed in the shape of graphs.
WARMWT
˖ water tank temperature, the first value is water tank real temperature, the second value in
‘ ( )’ is water tank setting temperature; the setting temperature is adjustable from 20
ć to 62ć, factory
setting is 45
ć.
ROOM
˖ Display room air temperature.
RETURN
˖ Display return water temperature.
FEED
˖
1.the first value is real feed water temperature, the second value in ‘( )’ is feed water setting
temperature in ROOMHEAT 1 mode, it is adjusted by slope of Curve according to outdoor ambient
temperature. Factory setting is that feed water temperature is 40
ć when outdoor ambient temperature is
0
ć, that is to say Curve is 40, the value of Curve is adjust from 22ć to 56ć. This setting is only
available for Room heating, not for water tank heating.
2. under ROOMHEAT 2 mode, FEED setting can be adjust directly from 20 to 65
ć, factory setting
is 45
ć; this setting is only available for room heating, not for water tank heating.
OUT
˖Display outdoor ambient temperature.
When at item WARMWT or RETURN or FEED, or BRINE IN or BRINE OUT, press button Right
BRINE IN:
Display the temperature of Brine system when entering the heat pump.
BRINE OUT: Display the temperature of Brine system when leaving the heat pump.
5 seconds willdisplay the information as follow kind of chart, to check how the temperature is going
in one hour.
3.1.2.5 Sub-Menu INTEGRAL
INTEGRAL
00
OFF
CMP
.
A
ADD 1
- 60
( 00)
( - 60)
- 500
00
ADD 2
( - 500)
- 550
ADD 3
( - 550)
- 600
TEMPERATURE
OUT
ROOM
FEED.
RETURN
WARMWT
BR . IN
25
28
45
30(65)
30(50)
BR . OUT
15