    Table of contents introduction...........................................................1 section one............................................................3 installing your scale................................................3 setup...............................................................

  • Page 3

    Introduction thank you for purchasing a setra quick count scale. Its ease of operation and durable construction should provide years of convenient and reliable service. While your scale is easy to operate, it is advisable to read this manual carefully before use. It is designed to help you perform w...

  • Page 4

    2 setra quick count™ operator's manual round weighing platform shown is used on scales of 5000 gram capacity or less. Adjustable foot level bubble keypad display weighing platform adjustable foot level bubble keypad display weighing platform rectangular weighing platform shown is used on scales of 2...

  • Page 5: Installing Your Scale

    Setra quick count™ operator's manual 3 section one installing your scale setup 1. Locating your scale the rugged design of your setra quick count scale ensures that it will operate well in typical factory or office environments. Nonetheless, you should treat your scale as you would any piece of prec...

  • Page 6

    4 setra quick count™ operator's manual power up the scale. The scale draws very little current from an outlet and may be left connected. This keeps your scale ready to use with no “ warm-up” time..

  • Page 7

    Setra quick count™ operator's manual 5 experimentation 1. Display test when your scale is first powered on, it automatically runs through a display test; lasting about six seconds. The scale next displays “ c nnn g” where nnn equals the full scale capacity in grams), performs self-diagnostics to ens...

  • Page 8: Understanding Your Scale

    6 setra quick count™ operator's manual section two understanding your scale keyboard functions zero assigns the pan and whatever is currently being weighed a value of zero. While the scale is determining a stable zero reading, the display will indicate “ busy” . Sample size displays preprogrammed sa...

  • Page 9

    Setra quick count™ operator's manual 7 display the weight on the pan exceeds the capacity of the scale; the pan is not properly seated or the scale is under loaded. Oflo the displayed count exceeds six digits (999,999). Update the scale is recalculating the average piece weight to enhance counting a...

  • Page 10: Using Your Scale

    8 setra quick count™ operator's manual section three using your scale basic weighing to weigh a sample on your scale, use the following procedure: 1. Press the zero key. 2. Place the object(s) to be weighed on the pan. 3. Wait for the “ ok” symbol, then read the weight from the display. Converting t...

  • Page 11: Tape/label

    Setra quick count™ operator's manual 9 basic counting using the sample size key to count a number of like objects on the scale, use the following procedure: 0.00 g clear print zero sample size count 1. Place an empty container on the scale. Press the zero key. ---------------------------------------...

  • Page 12

    10 setra quick count™ operator's manual using the minimum sample size and minimum accuracy feature counting errors can be caused by non-uniformity in the parts being counted or by insufficient sample weight. To reduce these errors your scale has been designed with two special features. The minimum s...

  • Page 13

    Setra quick count™ operator's manual 11 note: the accuracy enhancement feature is disabled if the average piece weight has been scanned in from a bar code or entered via a computer..

  • Page 14

    12 setra quick count™ operator's manual reverse counting or kitting using this feature, you can place a container full of pieces on your scale and count the number of pieces removed. This is especially helpful when kitting (counting out a certain number of pieces to be packed together). To perform r...

  • Page 15

    Setra quick count™ operator's manual 13 printing out information your setra quick count scale is designed to print out requested or stored information regarding a given batch when connected to an optional serial printer (see appendix i). To print out information using the setra model 240p or 340p do...

  • Page 16: Set-Up Functions

    14 setra quick count™ operator's manual appendix i set-up functions your setra quick count scale was programmed at the factory to operate in a prescribed manner. Many of the factory settings can be altered by an authorized setra dealer to optimize scale performance for your counting or weighing oper...

  • Page 17: Calibration

    Setra quick count™ operator's manual 15 appendix ii calibration your setra quick count scale is highly stable, and requires infrequent calibration. While it may be span calibrated as often as desired, the factory calibration is adequate for most counting applications. For precise weighing applicatio...

  • Page 18: Glossary of Terms

    16 setra quick count™ operator's manual appendix iii glossary of terms accuracy the degree of conformity of a measured value to the true value. Average piece weight the average weight in a sample of like pieces. Baud rate the rate at which your scale transmits or receives information to or from a co...

  • Page 19

    Setra quick count™ operator's manual 17 appendix iv rs-232 serial data communications your setra quick count comes equipped with a bidirectional rs-232 interface using a default baud rate of 2400 and no parity. Users who have purchased a setra 240p or 340p printer may simply follow the directions un...

  • Page 20

    18 setra quick count™ operator's manual for further information, obtain a copy of the setra quick count technician's guide by contacting your local authorized setra dealer..

  • Page 21: Accessories and Options

    Setra quick count™ operator's manual 19 appendix v accessories and options the following accessories are available for the setra quick count. Ask your dealer for current price information and/or a demonstration. Part number description 401150 240p printer - 40 column dot matrix tape printer comes pr...

  • Page 22: In Case of Difficulty

    20 setra quick count™ operator's manual appendix vi in case of difficulty setra quick count scales are designed to be easy to use. If, however, you have reached a state in which the scale will no longer follow your instructions, you may wish to “ reset” the scale. It is possible to do so by followin...

  • Page 23

    Setra quick count™ operator's manual 21 if the scale displays “ d-nos” , it may have been subjected to an extreme discharge of static electricity or power line fluctuations. The scale can be easily restored to operation by following the procedures outlined in steps #4 and #5 above. Note, the user se...

  • Page 24: Battery Option

    22 setra quick count™ operator's manual appendix vii battery option installation disassembly of the entire scale is not required when installing the battery option kit. 1. Position the back of the scale so it overhangs the rear of a work bench (see figure 2). 2. Remove the (2) phillips head screws (...

  • Page 25

    Setra quick count™ operator's manual 23 battery use for portable scale operation a fully charged battery will allow a setra scale to operate for approximately 24 hours before recharging is needed. The battery will last one-half as long or about 12 hours if the scale is equipped with an auto count 20...

  • Page 26: Specifications

    24 setra quick count™ operator's manual appendix viii specifications setra quick count capacity reproducibility readability non-linearity 2.2 lb +/-0.00002 lb 0.00002 lb +/-0.00002 lb 5.5 lb +/-0.00005 lb 0.00005 lb +/-0.00005 lb 11.0 lb +/-0.0001 lb 0.0001 lb +/-0.0001 lb 27.0 lb +/-0.0005 lb 0.000...

  • Page 27

    Setra quick count™ operator's manual 25 selectable parity*: even/odd/none display: 6-digit lcd pan: stainless steel operating temperature: 40• to 110•f (5• to 43•c) power supplied by ac adaptor: input - 110 vac / 60 hz output - 16.5 vdc @ 500 ma platform/pan dimensions: 1000 g (2.2 lb.) 5” diameter ...

  • Page 28: Setra Systems, Inc.

    26 setra quick count™ operator's manual appendix ix setra systems, inc. Limited two-year scale warranty setra systems, inc. Warrants the scales it manufactures to be free from defects in material and workmanship. Upon return, transportation charges prepaid, to setra’s factory within two (2) years of...

  • Page 29

    Setra quick count™ operator's manual 27 index ac adaptor, 3, 11, 17, 20, 22 accessories, 16 accuracy, 4, 5, 6, 9, 10, 12, 13, 14, 21 enhancement, 5, 9 add nnn, 6 auto count 200, 12, 15, 16, 20 average piece weight, 5, 6, 9, 12, 14 update, 9 bar code, 9, 12, 15, 16 wand, 15 battery, 3, 6, 16 charging...

  • Page 30

    28 setra quick count™ operator's manual pan, 3, 5, 22 parity, 11, 12, 14, 15, 22 pass, 17 pc, 5 pennyweights, 5, 7, 21 peripheral device, 5, 14, 18 pounds, 5, 7, 21 precision, 14 print, 5, 8, 11 print, 11, 12, 17 printer, 4, 5, 11 240p, 11, 12, 15, 16 340p, 11, 12, 15, 16 readability, 21 ref n.N, 6,...

  • Page 31

    Setra quick count™ operator's manual 29 fcc warning this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is ope...