Smartswitch SMS-2 Installation Manual

Summary of SMS-2

  • Page 1

    Smart switch sms-2 system monitor installation manual.

  • Page 2

    2 table of contents features 3 system / connections 4 outputs 5 inputs 6 commands getting started – setting up initial owner 7 adding a master 8 removing a master 8 adding an administrator 8 removing the administrator 9 get a list of all the masters 9 turn programmed numbers lookup on or off 9 text ...

  • Page 3: Features - Model Sms-2

    3 • receive text messages on your cell phone alerting you to potential problems anywhere in the world • send commands to control lights, pumps, appliances, air conditioning, etc. Via text message from your cell phone • connects to most gsm networks world-wide • module= duel band 900/1800mhz • up to ...

  • Page 4: Electrical Specifications:

    4 signal led: if the led flashes once every 1 second, this indicates the cellular network cannot be found (out of gsm coverage range). Remedy = re-locate the device or use a longer aerial or signal booster. If the led flashes once every 3 seconds, this indicates the cellular network has been found (...

  • Page 5: Outputs

    5 the sms-2 has two (2) outputs. The outputs are relays rated at 3 a resistive @ 125vac relay 1 connection internal relay relay terminals 7-8 outputs smart switch sms-2 installation & operation manual !! Important note !! A registered electrician must be used when connecting to the 120/240v main sup...

  • Page 6: Inputs

    6 the sms-2 has two (2) inputs and can be connected as per fig 1a /fig1b or fig 2 inputs smart switch sms-2 installation & operation manual sms-2 input 1 terminal 4 switch +10 - 30vdc fig 1a sms-2 input 2 terminal 6 switch +10 - 30vdc fig 1b sms-2 terminal 3 switch / input1 fig 2 switch / input2 ter...

  • Page 7: !! Important !!

    7 setting up system for the first time: please ensure the sim card does not have a pin number or is locked has been activated with the network provider, insert into sim slot on the back (see page 4) and power the unit up. When the unit is first powered on a mobile (cell phone) number must be set for...

  • Page 8: Commands

    8 adding a user (note: setting up the first user page 7 must be done first) command: add user +??Xxxxxxxx (see country code page 7) if the master is already in the list, the system responds with: sorry +??Xxxxxxxx is already active and cannot be added twice, please check the number and try again if ...

  • Page 9

    9 removing a administrator command: remove admin the system responds with: the administrator number and feature has been removed note: this completely removes the administrator from the user list, it does not move the user down a security level to normal “user” unless the administrator is the only n...

  • Page 10

    10 turn all input text’s off with alerts turned off the device will not text every time any input changes but the inputs are still active so you can send a “input status” query at any time. Command: alerts off the system responds with: alerts have been disabled (this is saved to memory and will stil...

  • Page 11

    11 naming inputs and outputs and changing names: command for initial naming or changing name of input or output: note: the system default names are: inputs: input1, input2 outputs: output1, output2 the name can contain a dash ( – ) but not a space. Eg. “pond-pump” is ok command: change current input...

  • Page 12

    12 change input to normally open or normally closed command: make input name active open (or) closed this command is used to define if the switch wired to the input is normally open or normally closed. The input defaults are set for a normally open switch (which is active closed). That is, the input...

  • Page 13

    13 link an input to an output command: link input name to output name (example: link alarm to siren) the system responds with: the input name has been linked to output name to clear a link command: clear input name link (example: clear alarm link) the system responds with: the link between input nam...

  • Page 14

    14 turn an output on or off command: turn output name on (or) off (example: turn generator on) if everything is fine, the system responds with: output name has been turned off (or) on this command is used to turn on/off outputs. If the item named is not an output or the command is not spelt correctl...

  • Page 15

    15 make an output pulse on and off command: make output name pulse xx secs this sets the output pulse time, xx can be between 1 and 99 seconds when the output on command is sent as follows: turn output name on the output will turn on for the programmed pulse time and then turn off, the system respon...

  • Page 16

    16 turn output response on / off this command is used to turn the output response text on or off. If the output response is turned off then a response text is not sent when outputs are turned on or off system default is on (send response). To turn the feature on: command: turn respond on the system ...

  • Page 17

    17 link the battery alarm to an output command: link battery alarm to output name the system responds with: the battery alarm has successfully been linked to output name and the alarm has been reset to clear or remove the link command: clear battery link the system responds with: the battery alarm o...

  • Page 18

    18 alive text feature. (only available in ver 1.2 or latter) this unit has an alive text feature which will send out a alive text as often as it has been programmed for. To turn the feature on: command: turn alive text on every xx yy (where xx=1 to 99, yy = hrs or days) this sets how often the alive...

  • Page 19

    19 get firmware version command: ver the system responds with: sms-2 ver x.X get signal strenth command: sig the system responds with: currently the signal strength is xx %" resetting the unit command: reboot the system responds with: module is not resetting reset unit to factory defaults ----------...

  • Page 20: Conditions of Warranty

    20 penguin electronics ltd (the manufacturer) warrants that all of its products are free of defects. Any apparent fault will be rectified free of charge by penguin electronics ltd for a period of 12 months from purchase date, provided that: all costs of installation, cartage, freight, travelling exp...

  • Page 21

    21 appendix one: record your names for all inputs and outputs input default name [name] (up to 20 characters ) latched yes no linked to active open or closed 1 input1 2 input2 output 1 output1 2 output2 smart switch sms-2 installation & operation manual detailed explanation of input delays: on delay...

  • Page 22: Trouble Shooting Guide

    22 trouble shooting guide problem cause possible solution led not flashing no power check power supply led fast flashes (every 1 second) and never slow flashes (every 3 seconds) cannot find the gsm network 1. Replace aerial with high gain aerial 2. Move unit to different location 3. Sim card not ins...

  • Page 23: ! Important Note !

    23 appendix two: sms-2 application notes figure 1 fixed wiring shore power monitoring (requires a registered electrician) smart switch sms-2 installation & operation manual - gnd sms-2 input 1 terminal 4 or input 2 terminal 6 + 120/230 vac to 12 vdc adapter plugged into vessel ac outlet and connecte...

  • Page 24

    24 intruder alarm systems the following configurations define possible solutions for intruder alarms. Like all other alerts provided by the sms-2, these should be disabled prior to you entering the premises. This is easily accomplished by issuing the text command: alerts off when leaving the premise...

  • Page 25

    25 door and window alarms alarms sensors for doors and windows generally consist of magnetically held switches. The contacts are normally-closed (nc). If a door/window is opened the circuit is opened generating an alarm. An alarm is also generated if the wire is cut between the sensor and the monito...

  • Page 26

    Air conditioners / heating different brands of air-con’s use different means of remotely turning on and off. Type1: if the brand requires that the output to be turned on and left on then you can use either output 1 or 4. Eg. Turning the output relay on will start the air-con and turning the relay of...

  • Page 27

    27 all technologies, design and intellectual property is owned by penguin electronics ltd new zealand version 2.1.