16
Turn Output response On / Off
This command is used to turn the output response text On or Off.
If the output response is turned off then a response text is not sent when outputs are turned
on or off System default is ON (send response).
To turn the feature on:
Command:
Turn respond on
The system responds with: This feature has been enabled, response text will be sent
To turn the feature off:
Command:
Turn respond off
The system responds with: This feature has been disabled, response text will not be sent
Save Output Status
This command is used to define if the output state is saved to memory and restored to it state
after a power recycle. E.g. if an output was On when the power was turned off then when the
power is restored the output will turn back on. Note this does not apply if an output was turned
on for a specified time. System default is not saved.
Command:
Make OUTPUT NAME save
The system responds with:
The output condition will be saved and restored if the power is reset
To turn the feature off:
Command:
Make OUTPUT NAME nonsave
The system responds with:
The output condition will not saved
Note: If you want this for both outputs then the command needs to be sent for both outputs
Set Battery Alarm Trigger Voltage
Command:
Change battery alarm to XX.X
Where XX.X can be between 8 and 30 volts
The system responds with:
The low voltage alarm has been set to XX.X
volts and the alarm has been reset
This system monitors the battery by calculating the average value of the supplied voltage over
the previous 1 minute period. Once this average has been detected to be below the set value
for the programmed time it sends a text message to inform all masters. The inclusion of the
running average helps protect the system from detecting inaccurate readings during periods
of increased load.
If no value (XX.X) is set the system responds with:
Because no value was specified the voltage alarm has been set to 11.5 volts and the
alarm has been reset
If the value (XX.X) is outside the settings the system responds with:
Because the value is out of range the voltage alarm has been set to 11.5 volts and
the alarm has been reset