3.2.3 Paper Feeding (Manual Feeding)
Under the normal work status, pres
s 【
FEED
】
button, the paper feeding begins, and stop when
loosen
【
FEED
】
button. When the printer works in black mark mode, press
【
FEED
】
button,
the printer begins to feed paper and stops over the position of black mark. If the paper is not the
black mark paper, the printer stops automatically after feeds paper for 30cm.
3.2.4 Self-Test
After receiving the printer, user can check its current setting and status at anytime.
Self-test way is as below: Power off, then hold down the
【
FEED
】
button and press the power
button at the same time. Then loosen the
【
FEED
】
button and power button when you hear ‘one
low one high ’prompt tone, the current setting and status will be printed out.
3.2.5
Hexadecimal Printing
The function of hexadecimal printing is to print the information received from host machine
by hexadecimal numbers and corresponding characters. It will be convenient to debug
application.
Into hexadecimal printing: Power off, hold down the
【
MODE
】
button and press the power
button at the same time. Then loosen the power button and press the
【
FEED
】
button when you
hear ‘one low one high’ prompt tone of power on. After that you may loosen the
【
MODE
】
button and
【
FEED
】
button. The printer turns into the hexadecimal printing mode and print the
presentation.
Quit hexadecimal printing :The way to quit hexadecimal printing mode is switch off the printer
or press the
【
FEED
】
button for three times. The printer will also print the presentation which
shows that the printer have quitted hexadecimal printing mode.
3.2.6
Printer Parameters Setting
This function may set some simple printing parameters.
Entering parameter setting: Switch off, then hold down the
【
MODE
】
button and press the
【
POWER
】
button at the same time. Then loosen the
【
POWER
】
button and
【
MODE
】
button
when you hear ‘one low one high ’prompt tone. The printer turns into the parameters setting
mode. Print out the first item which can be set parameters and the current numerical value.
Please see details in the appendix as below.
Quitting parameter setting:
Hold down
【
MODE
】
and
【
FEED
】
buttons, then loosen
【
MODE
】
button and
【
FEED
】
button. Saving the set parameter and exiting the parameter setting mode.