Sussman W500 Installation And Operating Instruction - page 5
4
Wiring Box Set Screw(s)
Wiring Box
Wiring Flange
Wiring Box
Wiring Flange
BX Connector Lock Nut
BX Cable*
(or greenfield)
*Note: NM (non-metallic) cable, if permitted by National
and Local Codes may be used instead of BX cable
*Note: WarmaTowel wires are color coded:
BLACK for LINE, WHITE for NEUTRAL,
GREEN/YELLOW for EQUIPMENT GROUND.
11. Slide the wiring box onto the wiring flange
and tighten the set screw firmly. Secure the
upper threaded flanges and lower bracket
with screws provided.
9. Secure wiring flange to the wall with screws
provided. (Use longer screws as required by
construction conditions.)
WARNING
!
8. Assemble the BX cable
connector to the wiring
flange as shown.
Models W542, W552 & W554 (cont.)
TO PREVENT SHOCK HAZARD, BE CERTAIN THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL
BEFORE ANY WIRING IS DONE.
10. Connect wiring per instructions pg. 7.
WARNING
!
If a single gang electric box has been roughed-in, see page 2 for instructions
WarmaTowel
Installation and Operating Instruction
®