T&C TC54.NG02.C Installation And Operating Instructions Manual - Log Set Assembly

Manual is about: COUNTRY HOME BURNER KIT

Summary of TC54.NG02.C

  • Page 1

    010410-16 tc54.Ng02.C 5056.4256.02 these instructions are supplementary to the installation and operating instructions supplied with the fireplace and should be kept together. Refer to the installation and operating instructions for proper gas supply, safety requirements and operating instructions. ...

  • Page 2: Package

    010410-16 tc54.Ng02.C • burnerassembly (including pilot and manifold) • loggrate(includingupper burner and pilot assembly) • embermaterial(twobags) • hardwarepackage 1. Remove ceramic filler piece from center of lower burner, set aside.Placethekeyholeslotsintheburneroverthetwoscrews located in the f...

  • Page 3

    Front connections red dot insulation sleeves 010410-16 tc54.Ng02.C 3. Attachthepilotsupplytubefromthelowerburnerpilottothe frontbulkheadfittingandtighten.(fig.#3)ensurethereareno leaks. 4. Transfer insulation sleeves from front electrical bulkhead connections to the pilot wires leading from the lowe...

  • Page 4

    Insulation sleeves rear connections red dot 010410-16 tc54.Ng02.C 8. Attachthepilotsupplytubefromtheupperburnerpilottothe rearbulkheadfittingandtighten.(fig.#9)ensurethereareno leaks. 9. Transfer the insulation sleeve from the rear electrical bulkhead connections to the pilot wires coming from the u...

  • Page 5: Propane Conversion

    010410-16 tc54.Ng02.C if the unit is to be used on propane convert as follows using the components supplied with this fireplace: warning this conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements o...

  • Page 6

    010410-16 tc54.Ng02.C 4. Applyasmallamountofpipejointcompoundtothethreadsof the propane burner orifice (marked # 43) to ensure a good seal, before screwing it into the fitting. (fig. #13) 5. Open shutter fully. (fig. #14) 6. Reinstall the manifold to the lower burner using the screws previ- ously re...

  • Page 7

    Fig. #17 fig. #18 fig. #19 fig. #20 010410-16 tc54.Ng02.C 12.Witha7/16”wrenchloosenthepilotheadonthepilotassembly attached to the lower burner assembly (fig. #17) 13.Slidethepilotadjustmentbandoverandensurethattheholein the orifice band is showing. (fig. #18 indicates ng position, fig. #19indicatesl...

  • Page 8

    16. Remove the minimum rate screw located in each valve. (fig. #21) 17. Replace the minimum rate screw with the one provided in the propaneconversionkitsuppliedwiththisfireplace.Ensurethat the screws are fully seated. (fig. #22) 18.Pullofftherubbercapfromthetopofthepressureregulator. (fig. # 23) 19....

  • Page 9: Gas Pressure Check

    010410-16 tc54.Ng02.C 1. Remove the plug from the pressure test port. The plug is located between the right side lintel and firebox side. (fig. # 26 & 26a) 2. Thread the extension test fitting into the open test port. (fig. # 27) 3. Attachapressuregaugeontothefitting. 4. Whentestingiscomplete,shutof...

  • Page 10: Ember Material

    010410-16 tc54.Ng02.C beforeaddingtheembermaterialpleaseensurethattheceramicfibrefillerpiecesarecor- rectly located in the bunrer as per figure #28. Two bags of ember material is shipped with the fireplace and need to be installed to ensure optimumperformanceandflameappearance. Pullapartthemateriali...

  • Page 11: Log Set Assembly

    010410-16 tc54.Ng02.C thelogsarefragile,andshouldbehandledwithcare.Unpackandinspectlogset.There should be a total of seven logs. Gas plumbing and vent connections should be completed before proceeding. Positionthelogsexactlyasindicatedbythefollowingpictures.Thethreemainlogshave holesand/orpins.Engag...

  • Page 12

    3 010410-16 tc54.Ng02.C 3 2 1 4 5 7 6 fig. #33 fig. #34 fig. #35 5 6 12.

  • Page 13: Burner Flame Adjustment

    010410-16 tc54.Ng02.C anairshutteroneachoftheburnertubescontrolstheprimarycombustionairtothegasburner andispresetclosedatthefactoryfornaturalgasfuel.Someadjustmentmaybenecessary toobtaindesiredflameandtoeliminatecarbondeposits.Evaluateflameappearanceafter thefireplacehasreachedoperatingtemperature.S...

  • Page 14: Replacement Parts

    13 12 4 7 11 10 9 8 6 5 3 4 7 2 1 010410-16 tc54.Ng02.C item description part no. 1 log grate assembly .........................................................................................Tc54.8181 2 lower burner assembly .............................................................................

  • Page 15: Notes

    010410-16 tc54.Ng02.C 15 notes.

  • Page 16

    Technical support: 1-250-748-1184 www.Townandcountryfireplaces.Net 2975 allenby rd., duncan, bc v9l 6v8 printedincanada.