T.E.M. A07B500S Manual - Installation
A07B500S manual
Pag. 17
INSTALLATION
4.1 Unpacking and inspection
Immediately, after the transmitter has been delivered, please carefully check the package to
verify possible damages caused by shipment. Should be found some damages, please
immediately contact the T.E.M. dealer.
It is recommended to keep the original package for a future shipment due to, for instance, repairing
or setting. A return with a package which is different from the original one will make the warranty
rights lost.
4.2 Installation
The transmitter A07B500S is composed of a 19 inches width rack which takes 3 units in height in a
vertical rack mount.
It is recommended to use 4 fixing plastic washers in order to avoid damages to the front panel
varnishing. We remind to carefully connect the earth both to the transmitter and to the rack mount-
never disconnect it without having switched the supply voltage off by the mains switch.
Design has considered the new rules concerning the electromagnetic compatibility so there aren’t
problems to locate systems CE marked nearby.
4.3 Power supply
AC power supply at 50/60Hz can be at 230V
AC
or 115V
AC
( opz.D )
The switching on control is placed for security reasons on the rear panel with the protection fuse,
which must have the value 6A for the higher voltage and 12A for the lower one and it must be a fast
type.
BEFORE SWITCHING THE TRANSMITTER ON, MAKE SURE
THAT THE POWER SUPPLY IS CORRECT AND CONNECT
THE RIGHT LOAD OR ANTENNA!