T.E.M. A07B500S Manual - page 31
A07B500S manual
Pag. 31
Among the various options in the main menu, there is the possibility of memorizing two
cellular phone numbers and the site or radio name to which the transmitter will send SMS
messages if an alarm or power up is detected. This pages are called “GSM number settings for
SMS send” and “transmitter site name setting for SMS send”.
Each phone number is composed
of a maximum of 16 numbers, with the first number occupying the mostleft-hand position, thelast
number being followed by the characters “:” up to the 16
th
position. After entering the first cellular
phone number, pressing ENTER will store the number; the cursor will then move automatically to
the second number, which can be entered in the same format. To send the alarm message, once the
transmitter is set and connected to the GSM via a serial cable, press the blue remote key, select
GSM, and press ENTER.
If an alarm or new power up is detected, the GSM will send the following messages:
RTL-GREEN VALLEY
RTL-GREEN VALLEY
ALARM FROM A07B500S
POWER UP FROM A07B500S
SERIAL NUMBER 4532
SERIAL NUMBER 4532
Date: 12/11/2001 10:31
Date: 12/11/2001 10:31
At this point, the user can connect to the transmitter with the detected alarm via a PC and verify
from the transmitted data the nature of the problem (failure or line power down), intervening with
the appropriate equipment to repair the failure.
The creation of an N+1 connection is possible with multiple transmitters. In this case, if
failure occurs, a “MASTER” (joker) transmitter substitutes the “SLAVE” transmitter in a system
where multiple radiating systems are operating in FM band.
A maximum number of 16 SLAVES can be connected to this system, and can all operate on various
powers and frequencies.