T Scale ATW series User Manual - 6.4 Capability Setting
ATW
digital weighing scales user’s guide
- 7 -
Check-weighing function enabled.
When a weight is placed on the scale the arrows will show if the weight is above or
below the limits and the beeper will sound as described below.
BOTH LIMITS SET
The display will show OK and the beeper will sound when the weight is
between the limits.
LOW LIMIT SET,
HIGH LIMIT is set to zero
The display will show OK and the beeper will sound when the weight is
less than the Low Limit. Above the Low Limit the display will show
HIGH and the beeper will be off.
HIGH LIMIT SET,
LOW LIMIT is set to zero
The display will show LOW and the beeper will be off when the weight
is less than the High Limit. Above the High Limit the display will show
OK and the beeper will be on.
BOTH LIMITS SET. LOW IS SET GREATER THAN HIGH
The beeper will never sound and the display will show LOW if the
weight is less that the LOW limit, and HIGH if the weight is greater than
the Low Limit.
NOTE: The weight must be greater than 20 scale divisions for the check-weighing to
operate.
To disable the Check-Weighing function enter zero into both limits when the current
limits are shown then pressing the ZERO/ENTER key to store the zero values.
6.4 CAPABILITY SETTING
Press the limit key and tare key and zero key to together during the weighing
model,
A factory constitution opening when user hear the buzzer "Di" sound.
Turn power off
and then turn it back on. The display will show
“ IN F “ press
anything key after hold the zero key the window show
“mode 1” . Press the tare key
select
“mode 2” press zero key to enter. The display show “- X-“ “X” it is current
capability, press the zero key sure .
Note : the display show
“ IN F “ at this time. The window show “ OUT F “ for press
the tare key , if user want to exit program command please press the zero key.