Takex PB-100TK Instruction Manual

Summary of PB-100TK

  • Page 1

    Photoelectric beam sensor instruction manual we appreciate your purchase of our photoelectric beam sensor. This sensor will provide long and dependable service when properly installed. Please read this instruction manual carefully for correct and effective use. Please note: this sensor is designed t...

  • Page 2

    Points of installation heights of installation install the sensor at a height of 31" to 39" (80 to 100cm) to catch human pattern. Position of installation using the adjustments, the lens can move horizontally ( ±90 degrees) and vertically (±10 degrees) allowing the unit to work in all directions. ( ...

  • Page 3

    1) remove cover from unit and slide the mounting plate to detach it. 2) pull wire through on the installation site. 3) break grommet on mounting plate and pull wire through it. Secure the plate with 4mm screws. Pull wire through sensor body (back to front) and attach it to the mounting plate. 4) whe...

  • Page 4

    Symptom possible cause remedy operation led 1. No power supply. 1. Turn on the power. Does not light 2. Bad wiring connection or broken wire, short. 2. Check wiring. Alarm led does 1. No power supply. 1. Turn on the power supply. Not light when the 2. Bad wiring connection or broken wire, short. 2. ...