POINTS OF INSTALLATION
Heights of installation
Install the sensor at a height of 31" to 39" (80 to
100cm) to catch human pattern.
Position of installation
Using the adjustments, the lens can move
horizontally ( ±90 degrees) and vertically (±10
degrees) allowing the unit to work in all directions.
( example 1 to 3)
Vertical
adjustment
screw
±10˚
±90˚
Horizontal
adjustment
Exemple 1
Exemple 2
Exemple 3
CAUTIONS ON INSTALLATION
•
Avoid overhead wiring
•
When installing indoors, wiring procedures
similar to those for telephones or intercoms are
acceptable.
Outdoor wires should be placed inside pipes, or
underground cable / metal shielded cable should
be used.
Terminal configuration
Connection
Power
10V to 30VDC (non-polarity)
Power
10V to 30VDC
(non-polarity)
[Receiver]
[Transmitter]
Alarm
NC
NC
COM
NO
Alarm output
Dry contact relay
Output 1c
30V (AC/DC) 0.5A
When cover
attached
Tamper output
Dry contact relay
Output N/C 30V
(AC/DC) 0.5A
•
Wiring distance
model
PB-30TK
PB-60TK, PB-100TK
voltage
12V
24V
12V
24V
wire size
AWG22
720’
6200’
490’
4200’
(Dia 0.65mm)
(220m)
(1890m)
(150m)
(1280m)
AWG20
1200’
10500’
830’
7200’
(Dia 0.8mm)
(366m)
(3200m)
(250m)
(2200m)
AWG18
1800’
16000’
1200’
10500’
(Dia 1.0mm)
(549m)
(4880m)
(366m)
(3200m)
AWG17
2200’
20000’
1450’
13500’
(Dia 1.1mm)
(670m)
(6000m)
(442m)
(4000m)
Note 1) Maximum wiring distance when two or more sets are connected
is the value above divided by the number of sets.
2) The signal line can be wired to a distance of up to 3,300 ft.
(1,000m) with AWG22 (dia 0.65mm) telephone wire.
•
Example connection 1
•
Example connection 2
•
Example connection 3
Transmitter
Receiver
Control panel
(12VDC)
Power
Alarm
signal
TR.
RE.
TR.
RE.
TR.
RE.
TR.
RE.
Control panel
(12VDC)
Power
Alarm
signal
Control panel
(12VDC)
Power
Alarm (1ch.)
Alarm (2ch.)
31" to 39"
(80 to 100cm)