Takex PR-11BE Instruction Manual - Installation
4
INSTALLATION
3
WIRING
−
+
Power
10.5V to 30VDC
(non-polarity)
Alarm
NC
NO
COM
Alarm output
Dry contact relay
output 1c N/O-N/C
NC
Tamper output
Dry contact relay
output 1b N/O
When cover is
detached
●
Example connection 1
●
Example connection 2
●
Example connection 3
Power
Alarm(1ch.)
Alarm(2ch.)
Power
Alarm
signal
Power
Alarm
signal
Control panel
(12VDC)
Control panel
(12VDC)
Control panel
(12VDC)
①Remove cover from
unit and slide the
mounting plate
upwards to detach
it.
②Pull the wire through on the installation site.
③Make one hole in the grommet on the mounting plate and
pull the wire through it.
Secure the plate with 4mm self tapping screws
④When the wiring is exposed , break knockouts (2 positions)
on the rear of the unit, pull the wire through as in the figure
and attach it to the terminals on the sensor.
Wiring from
the bottom
Wiring from
the top
Knockout
Knockout
※The grommet is compatible with a wire of φ0.12" (φ3mm)
to φ0.24" (φ6mm) outer dia.
When a wire of more than φ0.24 (φ6mm) outer dia. is used,
cut off the dotted line portion on the below figure using
pliers or the like.
Then use caulking to prevent insects from entering into the
unit.
① ② ③ ④ ⑤ ⑥ ⑦
▼
▼
Wire size
Voltage
DC24V
DC12V
5,610' (1700m)
9,240' (2800m)
13,860' (4200m)
16,830' (5100m)
500' (150m)
990' (300m)
1,490' (450m)
1,815' (550m)
AWG 22 (Dia 0.65mm)
AWG 20 (Dia 0.8mm)
AWG 18 (Dia 1.0mm)
AWG 17 (Dia 1.1mm)
①②③④
①②③④
①②③④
①②③④
①②③④
}
}
}
}
.
.
}
}
}
.
.
●
Sensor
TERMINAL CONFIGULATION
Maximum wiring distance when two or more sets are
connected is the value above divided by the number of
sets.
●
Wiring distance
Note)
CONNECTION
WALL MOUNT
⑤After wiring is completed, adjust alignment, attach cover
and check operation.
(Note : Sealing is not required for unit surround due to
rain-proof construction.)
3.29" (82.5mm)
holes
middle point of the
sensor lenses
Self tapping screw
Pull the wire through the sensor body (back to front)
and attach it to the terminals on the sensor.
Grommet