T6218 Maintenance Manual Supplement
24
Tally Printer Corp. P/N 1149-084775
Procedure 13: Distribution PCA Removal
Step 1:
Remove the Ribbon Platform (Procedure 1)
Step 2:
Unplug all the connectors on the Distribution PCA.
Step 3:
Remove the two cable clamps and unplug the hammer bank cables at
the hammer bank.
Figure 5. Hammer Bank Cable Clamp Locations
Step 4:
Remove four (4) screws that mount the Distribution PCA to the surge
capacitors.
Figure 6. Distribution PCA Screws
Reverse the steps to install a new assembly.
Cable
Clamps