Tally T6218 Maintenance Manual Supplement - page 26
T6218 Maintenance Manual Supplement
26
Tally Printer Corp. P/N 1149-084775
Procedure 21: Platen Sensor PCA Removal
The following instructions are valid for the T6215 and T6218. The Platen Sensor PCA is located
under the left side of the printer mechanism, just above the Power Supply. To remove the
Sensor PCA, follow these steps:
Figure 9. Platen Sensor PCA Location
Step 1:
Remove the Ribbon Platform.
Step 2:
Remove the Control Panel Assembly.
Step 3:
Unplug the Power Supply cable and the Hammer Bank cable from the
Power Distribution PCA.
Step 4:
Lift the Print Mechanism, placing the Strut in the top and bottom
detents to hold the Print Mechanism in a tilted position.
Figure 10. Platen Sensor PCA
Step 5:
Disconnect the cables from the Platen Sensor PCA.
Step 6:
Remove the two screws (#6 Phillips) that attach the circuit board to the
side frame and lift the board clear.
Reverse the order of removal steps for installation.
Platen Sensor PCA -
(Print mech tilted)
Left Tractor -
Moved for access