Storing the External Charger
Remove the battery before disconnecting the adapter from the unit.
Always disconnect the charger from the AC adapter and the AC adapter from the AC by pulling on the plug and not
on the cord.
Store the unit in a dry environment.
Specifications
Input voltage:
12.0V–26.0VDC
Input current:
1.1A max
Input overcurrent and reverse: Fuse protection
Charge voltage:
8.4V
Charge voltage tolerance:
±1%
Nominal fast charge current:
1A
Charge current tolerance:
±20%
Precharge threshold:
6.0V typ
Precharge current:
300mA
Efficiency:
85% min
Charge time:
4 hrs. max.
Charge timeout limit:
6.0 hrs.
Charge operation temperature:
0-50 °C
Humidity
0-85% non-condensing
Regulatory Information
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference
that may cause undesired operation.
This unit has been tested and found to be compliant with the following requirements:
EN 55014-1:2000 + A1:2001 + A2: 20002,
EN 61000-3-2: 2000 + A2: 2005,
EN 61000-3-3: 1995 + A1: 2001,
EN 55014-2: 1997 + A1: 2001,
FCC PART 15, SUBPART B: 2004
•
•
•