11
Model 337
Controls and Systems
The SET STANDBY TEMPERATURE screen displays
the current temperatures of both freezing cylinders.
SET STANDBY TEMP
STANDBY TEMP:
30.0
PRESENT :
30.0
+ + +
-- -- --
SEL
Pressing the MENU/SEL key accepts the setting and
returns to the Service Menu.
Set Hopper Temperature
(Option E)
The exit temperature of the hopper cooling system
refrigerant can be adjusted through this screen.
The current temperature is also displayed. The factory
default setting is 40_F (4_C). The minimum setting is
30_F (--1_C) and the maximum setting is 40_F (4_C).
Pressing the WASH (+ + +) or AUTO (-- -- --) keys
increase
or
decrease
the
temperature
by
1/2_respectively. The differential between cycle off
and cycle on is 12_F (6_C).
SET HOPPER TEMP
HOPPER TEMP:
39.0
PRESENT :
38.0
+ + +
-- -- --
SEL
Pressing the MENU/SEL key accepts the setting and
returns to the Service Menu.
Compressor Cycle Time
(Option F)
This setting determines the length of time the
compressor will remain off after a freeze cycle is
complete. The numbers represent minutes and can be
adjusted for a minimum of three minutes to a maximum
of 16 minutes. The factory default setting is 10
minutes. The compressor cycle time can be increased
or decreased by increments of one minute. The
compressor OFF cycle time should not allow the OFF
cycle temperature to rise more than 2_.
COMP CYCLE TIME
CYCLE TIME: 10 MIN
+ + +
-- -- --
SEL
Pressing the MENU/SEL key accepts the setting and
returns to the Service Menu.
Beater Off Delay
(Option G)
This setting will allow the beater motor to continue
running after the compressor has cycled off. The
factory default setting is zero; however, the beater
motor can be adjusted to run after the compressor
cycles off. The minimum setting is 0 and the maximum
setting is 10. The beater off delay can be increased or
decreased by increments of 1 second.
BEATER OFF DELAY
TIME: 0 SECONDS
+ + +
-- -- --
SEL
Pressing the MENU/SEL key accepts the setting and
returns to the Service Menu.
Compressor On Delay
(Option H)
This setting will allow the beater motor to start before
the compressor activates. Standard operation allows
the beater motor and compressor to start
simultaneously; therefore, the factory default setting is
zero. However, the compressor delay can be adjusted
so the compressor is activated after the beater motor
starts.
The minimum setting is 0 and the maximum setting is
10. The compressor on delay can be increased or
decreased by increments of 1 second.
COMP ON DELAY
TIME: 0 SECONDS
+ + +
-- -- --
SEL
Pressing the MENU/SEL key accepts the setting and
returns to the Service Menu.