Taylor 340 Operator's Manual - page 6
2
Models 340, 341, 342
To the Installer
110105
Water Connections
(Water Cooled Units Only)
An adequate cold water supply with a hand shut-off
valve must be provided. On the underside of the base
pan, two 3/8” I.P.S. (for single-head units) or two 1/2”
I.P.S. (for double-head units) water connections for
inlet and outlet have been provided for easy hook-up.
1/2” inside diameter water lines should be connected
to the machine. (Flexible lines are recommended, if
local codes permit.) Depending on local water
conditions, it may be advisable to install a water
strainer to prevent foreign substances from clogging
the automatic water valve. There will be only one water
“in” and one water “out” connection for both
double-head and single-head units. DO NOT install a
hand shut-off valve on the water “out” line! Water
should always flow in this order: first, through the
automatic water valve; second, through the
condenser; and third, through the outlet fitting to an
open trap drain.
Air Cooled Units
The model 340 air cooled unit requires a minimum of
6” (152 mm) of clearance around both sides of the
freezer. It is recommended to install a skirt to one side
of the unit, and to place the back of the unit against a
wall. The models 341 and 342 air cooled units require
a minimum of 3” (76 mm) of air clearance around all
sides.
Failure to allow adequate clearance can reduce the
refrigeration capacity of the freezer and possibly
cause permanent damage to the compressor.
Electrical Connections
In the United States, this equipment is intended to be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70- 1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each freezer requires one power supply for each data
label. Check the data label(s) on the freezer for branch
circuit overcurrent protection or fuse, circuit ampacity
and electrical specifications. For proper power
connections, refer to the wiring diagram provided
inside of the electrical box.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.