Taylor C300 NP Operator's Manual

Manual is about: Slush Freezer

Summary of C300 NP

  • Page 1

    Operator's manual model c300np non-pressurized slush freezer original operating instructions 055072np 9/22/06 (original publication) (updated 7/1/15).

  • Page 2

    Complete this page for quick reference when service is required: taylor distributor: address: phone: fax: e-mail: service: parts: date of installation: information found on the data label: model number: serial number: electrical specs: voltage cycle phase maximum fuse size: a minimum wire ampacity: ...

  • Page 3: Table Of Contents

    Table of contents model c300np table of contents section 1 to the installer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 2 to the operator 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 3 safety 5 ....

  • Page 4

    Model c300np table of contents table of contents - page 2 section 7 important: operator checklist 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . During cleaning and sanitizing 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting bacteri...

  • Page 5: Section 1

    1 model c300np to the installer 131210 section 1 to the installer the following information has been included in the manual as safety and regulatory guidelines. For complete installation instructions, please see the installation checklist. Installer safety in all areas of the world, equipment should...

  • Page 6

    2 model c300np to the installer 071010 water cooled refrigeration units (water cooled units only) on the back of the unit, two additional 3/8” (9.5 mm) f.P.T. Water connections for condenser inlet and outlet have been provided for easy hook-up. 3/8” (9.5 mm) inside diameter water lines should be con...

  • Page 7

    3 model c300np to the installer 131210 electrical connections in the united states, this equipment is intended to be installed in accordance with the national electrical code (nec), ansi/nfpa 70-1987. The purpose of the nec code is the practical safeguarding of persons and property from hazards aris...

  • Page 8: Section 2

    4 model c300np to the operator 131210 section 2 to the operator the freezer you have purchased has been carefully engineered and manufactured to give you dependable operation. The model c300np, when properly operated and cared for, will produce a consistent quality product. Like all mechanical produ...

  • Page 9: Section 3

    5 model c300np safety 131210 section 3 safety we, at taylor company, are concerned about the safety of the operator when he or she comes in contact with the freezer and its parts. Taylor has gone to extreme efforts to design and manufacture built-in safety features to protect both the operator and t...

  • Page 10

    6 model c300np safety 131210 do not use a water jet to clean or rinse the unit. Failure to follow these instructions may result in serious electrical shock. Caution: this unit is pressurized when in operation. The control switch must be in the off position until the unit is completely assembled. No ...

  • Page 11: Section 4

    7 model c300np operator parts identification 150427 section 4 operator parts identification figure 2 item description part no. 1 panel-side-left 054676 2 panel-rear 054672 3 panel-side-right 054671 4 display-lighted 054683-27 5 panel-front-upper 069142 6 panel-front-shell 054668 item description par...

  • Page 12

    8 model c300np operator parts identification 150427 beater door assembly figure 3 item description part no. 1 door a.-slush-slfclose- ice buster items 1a-1i 1a buster-ice 047735 1b spring-comp.970x.082x3.87 030344 1c pin a.-valve handle x83812 1d valve-draw self close 080662 1e o-ring-1"od x .139w 0...

  • Page 13

    9 model c300np operator parts identification 141212 accessories figure 4 item description part no. 1 pail-10 qt 013163 2a brush-mix pump body-3”x7” 023316 2b brush-double ended 013072 2c brush-rear brg 1”dx2“l 013071 item description part no. 2d brush-draw valve 1-1/2”od 014753 3 kit a.-tune up x568...

  • Page 14: Section 5

    10 model c300np important: to the operator 141212 section 5 important: to the operator figure 5 item description 1 product light - left side 2 control switch 3 keypad - left side 4 liquid crystal display 5 keypad - right side 6 product light - right side symbol definitions to better communicate in t...

  • Page 15

    11 model c300np important: to the operator control switch the control switch is located at the top left corner of the control channel. When placed in the on position, allows slushtech operation. Liquid crystal display the liquid crystal display (lcd) is located on the front control panel. The lcd is...

  • Page 16

    12 model c300np important: to the operator operator menu timeout if the display is left in the operator menu or any of the operator menu selections, except for current conditions, the display will return to the system mode screen 60 seconds after the last keypress. The current conditions screen will...

  • Page 17

    13 model c300np important: to the operator 6. Syrup press low - when the syrup out indicator displays a lack of syrup, the unit will enter a hold mode. At this time, no refrigeration or product flow from the flow control will be allowed. Only the beater will operate. When the syrup is satisfied, the...

  • Page 18

    14 model c300np important: to the operator screen c is set clock. Use the auto (- ->) and off ( element to be set (hours, minutes, month, day, or year). Use the prime (+++) and beater (- - -) keys to increment or decrement the value. Press the menu (sel) key to advance to the daylight saving time sc...

  • Page 19

    15 model c300np important: to the operator the fourth feature will display the power saver mode, off, rest, or standby status. If the power saver mode is off, the following screen will be displayed. Power saver mode off sel if a power saver mode is programmed, one of the following screens will appea...

  • Page 20

    16 model c300np important: to the operator press the auto (- ->) key to move to the next screen. The next screen will indicate when the fault was satisfied. Fault history 2 10/25/06 14:06:19 restored from fault page 2 + + + - - - sel press the menu (sel) key to return to the operator menu. Screen h ...

  • Page 21

    17 model c300np important: to the operator co 2 out indicator auto mode auto ok syrup ok co2-out water-ok on the lcd, if the word “out” appears next to the word “co2” it indicates a lack of co2 being supplied to the freezer. The product light will also illuminate and a warning tone will sound. This ...

  • Page 22: Section 6

    18 model c300np operating procedures section 6 operating procedures the model c300np contains two 7 quart (6.6 liter) freezing cylinders. The syrup flow control combines the two ingredients of water and syrup, and sends this combination to the freezing cylinder. As product is drawn, new product will...

  • Page 23

    19 model c300np operating procedures 150701 step 3 before installing the beater assembly, check the scraper blades for any signs of wear or damage. If a scraper blade is nicked or worn, replace both blades. Check the scraper blade clips to make sure they are not bent and the slot is even for the ent...

  • Page 24

    20 model c300np operating procedures 141212 step 9 install the o-rings on the draw valve and lubricate. Figure 12 step 10 turn the door upside down. Insert the draw valve spring. Figure 13 step 11 insert the draw valve into the door. Line up the small hole on each side of the draw valve with the slo...

  • Page 25

    21 model c300np operating procedures 141212 step 14 from the back of the door, install the ice buster through the door spout and into the slot located just above the lower o-ring. Figure 17 step 15 move the draw handle to the back position to lock the ice buster in place. Figure 18 step 16 turn the ...

  • Page 26

    22 model c300np operating procedures 141212 step 18 place the o-ring onto the prime plug and lubricate. Figure 21 step 19 screw the prime plug into position on the front of the door. Figure 22 step 20 place the large rubber gasket into the groove on the back side of the freezer door. Figure 23 step ...

  • Page 27

    23 model c300np operating procedures 141212 step 23 position the baffle arm by inserting it down into the hole on the baffle assembly which protrudes from the door. Verify proper installation by moving the baffle arm back and forth to be sure it moves freely. Figure 26 repeat steps 1 through 23 for ...

  • Page 28

    24 model c300np operating procedures step 5 with the bag connector attached to the syrup line, place the syrup line into the pail of sanitizing solution. Figure 30 step 6 to place the left freezing cylinder in the sanitize mode, press the menu (sel) key. Move the cursor by pressing the auto (- ->) k...

  • Page 29

    25 model c300np operating procedures 150701 step 9 continue filling the freezing cylinders with sanitizing solution until the solution purges out of the vent at the top of the mix tank, and begins draining into the front drip tray. Press the off ( step 10 press the beater (- - -) key. Agitate the so...

  • Page 30

    26 model c300np operating procedures 150701 step 6 slowly move the syrup sampling valve to the fully open position by turning the handle “down” toward the sampling line. Allow the liquid to run into a pail until all the sanitizer is removed and full strength product is flowing. Figure 35 important! ...

  • Page 31

    27 model c300np operating procedures step 10 once the proper brix has been achieved, turn the handle “up” to allow product to flow to the mix tank. Figure 39 note: the position of the handle on the syrup sampling valve determines the direction of product flow. The down position opens the syrup sampl...

  • Page 32

    28 model c300np operating procedures draining product from the freezing cylinder step 1 press the beater (- - -) key. This will allow the beater to operate to push the product from the freezing cylinder. Open the draw valve and drain the product from the machine. Figure 41 step 2 when all the produc...

  • Page 33

    29 model c300np operating procedures 141212 cleaning step 1 prepare two gallons (7.6 liters) of an approved cleaning solution (examples: stera sheen or kay-5 r ). Use warm water and follow the manufacturer's specifications. Important: make sure the cleaner is completely dissolved. Step 2 pour the cl...

  • Page 34

    30 model c300np operating procedures 141212 brush cleaning step 1 prepare a sink or a pail with an approved cleaning solution. Use warm water and follow the manufacturer's specifications (examples: stera sheen or kay-5 r ). Important: follow the label directions. Too strong of a solution can cause p...

  • Page 35: Section 7

    31 model c300np important: operator checklist 080926 section 7 important: operator checklist during cleaning and sanitizing always follow local health codes cleaning and sanitizing schedules are governed by your state or local regulatory agencies and must be followed accordingly. The following check...

  • Page 36

    32 model c300np important: operator checklist winter storage if the place of business is to be closed during the winter months, it is important to protect the freezer by following certain precautions, particularly if the building is subject to freezing conditions. Disconnect the freezer from the mai...

  • Page 37: Section 8

    33 model c300np troubleshooting guide section 8 troubleshooting guide problem probable cause remedy page ref. 1. Product is too stiff. A. Too much water to syrup ratio. Improper brix adjustment. A. Adjust the brix accordingly. 26 b. Consistency control needs adjustment. B. Contact a service technici...

  • Page 38

    34 model c300np troubleshooting guide 150701 problem probable cause remedy page ref. 6. Unable to remove the drive shaft from the rear shell bearing. A. Rounded corners of hex end of drive shaft, drive coupling, or both. A. Replace the drive shaft, or call a service technician to replace the direct ...

  • Page 39

    35 model c300np troubleshooting guide problem probable cause remedy page ref. 12. Lack of syrup being supplied to machine. A. Loss of co 2 to propel syrup. A. Contact a service technician. - - - b. Clogged or kinked syrup lines. B. Sanitize syrup lines regularly. If kinked, repair or replace. - - -.

  • Page 40: Section 9

    36 model c300np parts replacement schedule section 9 parts replacement schedule part description every 4 months every 8 months annually scraper blade x drive shaft seal x drive shaft o-ring x freezer door gasket x draw valve o-ring x front bearing x prime plug o-ring x black bristle brush, 1” x 2” i...

  • Page 41

    37 model c300np limited warranty on equipment 131210 section 10 limited warranty on equipment taylor company limited warranty on freezers taylor company, a division of carrier commercial refrigeration, inc. (“taylor”) is pleased to provide this limited warranty on new taylor-branded freezer equipmen...

  • Page 42

    38 model c300np limited warranty on equipment 3. Replacement of wear items designated as class “000” parts in the taylor operator’s manual. 4. External hoses, electrical power supplies, and machine grounding. 5. Parts not supplied or designated by taylor, or damages resulting from their use. 6. Retu...

  • Page 43: Section 11

    39 model c300np limited warranty on parts 131210 section 11 limited warranty on parts taylor company limited warranty on taylor genuine parts taylor company, a division of carrier commercial refrigeration, inc. (“taylor”) is pleased to provide this limited warranty on new taylor genuine replacement ...

  • Page 44

    40 model c300np limited warranty on parts limited warranty exceptions this limited warranty does not cover: 1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of defective parts, replacement parts, or new parts. 2. Normal maintenance, cl...

  • Page 45

    41 model c300np limited warranty on parts limitation of warranty this limited warranty is exclusive and is in lieu of all other warranties, conditions and/or remedies under the law, including any implied warranties or conditions of merchantability or fitness for a particular purpose. The original ow...