TE 1804116-1 Customer's Manual - page 7
409-10060
Rev D
7 of 11
4.2.
Attaching the Battery Cartridge
1. Pull out on the battery cartridges while pressing the latch (see Figure 2).
2. To install the two battery cartridges, push them firmly into place.
NOTE
Always install and use both battery cartridges at the same time.
Figure 2
3. After attaching the battery cartridges, verify they are in place by pulling them without pressing the latch.
NOTE
To activate a 28.8 VDC motor, two
battery cartridges must be inserted into the cartridge slots since they are connected “in
series”.
4.3.
Attaching the Hydraulic Hose
1. Attach the female coupler of the hydraulic tool to the male coupler of the hydraulic pump as shown in
Figure 3.
Figure 3
2. Gently pull on couplers to verify they are securely connected.
NOTE
If couplers are not engaged properly, the ram will advance but will not retract.
3. Attach the application head to the opposite side of the hose (if not already attached).
Press Latch
Pull Battery
Cartridge Out
No Gaps
Male Coupler of
Hydraulic Pump
Coupler Ring
Female Coupler of