4.4.
Attaching the Remote Control Cord
Attach remote control cord to the pump. Remove cap from the receptacle at the pump. Then insert plug of
control cord and tighten ring securely (the attached cord should resemble as shown in Figure 4).
Figure 4
4.5.
Controlling the Pump
To advance the piston, press and hold "UP" button.
To retract piston, press and hold “DOWN” button (see Figure 5).
NOTE
When hydraulic power reaches 68.95 MPa [10,000 psi], the motor shuts off, and compression is complete.
Figure 5
4.6.
Guide to Crimping Capacity
NOTE
The following values are approximate and can vary according to charging and crimping conditions.
The battery can be charged approximately 500 cycles.
Cable size is 750 MCM
Average number of crimping cycles is 50 times
When the crimping cycle is reduced to approximately one-half the normal cycle, the battery life is
exhausted and the battery should be replaced.
Remote
Control
Cord
Plug of Remote
Control Cord
“UP”
Button
“DOWN”
Button