7
MACHINE PREPARATION
5. Place the batteries in their compartment.
6. Connect the batteries’ connector (2) to the machine’s connector (1).
7. Reassemble the recovery tank, vacuum plug and squeegee hose.
3. CONNECTING THE BATTERY CHARGER
The battery chargers’ connector fits into the battery connector (2) located under the
recovery tank.
4.
CHARGING THE BATTERIES
Make sure the battery charger is for use with the installed battery, both capacity and
type (lead/acid or GEL).
WARNING! NEVER CHARGE A GEL BATTERY WITH
AN INCORRECT BATTERY CHARGER.
NEVER ALLOW THE BATTERIES TO RUN COMPLETELY DOWN
, recharge them
within a few minutes after the battery indicator starts blinking.
Never leave the batteries
completely discharged
, even if the machine is not being used.
When charging the batteries, keep the recovery tank lifted with the prop as shown in
the figure.
Turn the key to the OFF position. Connect the DC connector on the charger to the
DC battery connector. Connect the AC charger plug to a receptacle that has the
correct voltage and frequency for your charger. Make sure the receptacle is
connected to the electrical ground.
WARNING!
When charging the batteries, follow all the instructions
provided with this manual and the battery charger. Trained staff must carry
out the installation and maintenance operations.
WARNING! Fire Danger:
Lead acid batteries generate gases that can cause
an explosion. Keep sparks and flames away from batteries.
NO SMOKING!
WARNING!
To prevent an explosion, charge the batteries only in an area
with good ventilation.
WARNING!
Always wear eye protection and protective clothing when
working near batteries.