• In the LPF measuring mode, the meter will turn to manual
mode. Press the RANGE key to select a range. When the
low-pass filter is enabled, automatic range is unavailable.
• Do not input a voltage above 1000V. Higher voltage may
be measured but it poses the risk of damaging the meter.
• After completing all measurements, disconnect the
connection between the test leads and the circuit under
test.
14. dBV
1) Insert the red test lead into the V terminal and the black
test lead into the COM terminal.
2) Set the rotary switch to v. Connect the test leads to the
power or load to be tested in parallel as shown in
Figure 5.
3) Press the function key labelled, “MENU” to choose
measuring options. Press the cursor keys
to
highlight “dBV”, then press the function key labelled,
“dBV” to enter dBV measurement mode.
4) dBV is the primary measurement shown and AC voltage
value is the secondary value shown on the display. AC
voltage of the measured signal is also displayed on the
15. dBm
1) Insert the red test lead into the V terminal and the black
test lead into the COM terminal.
2) Set the rotary switch to V. Connect the test leads to the
power or load to be tested in parallel as shown in
Figure 5.
3) Press the function key labelled, “MENU” to choose
measurement options. Press the cursor keys
to highlight “dBm”. A reference impedance must be
used to calculate the dBm measurement. Press the
function key labelled, “RES” to select a reference
impedance value. Press
(UP) or (DOWN) to scroll
between ten defined reference values: 4, 8, 16, 25, 32,
50, 75, 600, 1000Ω, and User Defined. While selecting
a User defined reference impedance, press the function
key labelled, “EDIT” and use the cursor keys
to
input a reference impedance value between
4-1,200Ω. Press the function key labelled, “OK” to set
reference values. Press the function key labelled, “dBm”
to enter dBm measurement.
4) dBm is the primary measurement shown and AC voltage
value is the secondary value shown on the display. AC
voltage of the measured signal is also displayed on the
simulation bar.
16. Maximum and Minimum Value
Press the “MAX MIN” key to activate Max Min Mode.
Real-time measurements are the primary value displayed.
Maximum, minimum, and average values, as well as
elapsed time, start date and times corresponding to the
three values are secondarily displayed.