U-Line 3024DWR User Manual

Other manuals for 3024DWR: User Manual & Service Manual
Manual is about: Modular 3000 Series 24" Drawer Model

Summary of 3024DWR

  • Page 1

    User guide safety • installation & integration • operating instructions • maintenance • service modular 3000 series • 3024dwr • 24" refrigerator drawers right product. Right place. Right temperature. Since 1962..

  • Page 2

    User guide u-line.Com contents safety • installation & integration • operating instructions • maintenance • service intro safety safety and warning disposal installation environmental requirements electrical cutout dimensions product dimensions anti-tip bracket general installation integrated grille...

  • Page 3

    User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, d...

  • Page 4

    User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow...

  • Page 5

    User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...

  • Page 6

    User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this unit is designed to operate between 50°f (10°c) and 100°f (37°c). High ambient temperatures (100°f [37°c] or higher) may reduce the ...

  • Page 7

    User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...

  • Page 8

    User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space ...

  • Page 9

    User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 33-11/16" to 34-11/16" (856 mm to 881mm) 3-5/8" to 4 5/8" (92 to 118 mm) 23 5/8" (600 mm) not including handle 23-7/16" (590 mm).

  • Page 10

    User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket caution ! The anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened or excess weight is placed on the front of the ...

  • Page 11

    User guide anti-tip bracket 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 5. Using a 3/32" drill bit, drill 3 pilot holes 5/8" (16 mm) deep into cabinetry frame using the anti-tip bracket as a template. 6. Install the 3 remaining #8x5/8" screws int...

  • Page 12

    User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation leveling information 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not...

  • Page 13

    User guide integrated grille - plinth dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated grille - plinth dimensions prepare and install integrated grille (plinth strip/base fascia) 1. Use the dimensions provided in the diagram to c...

  • Page 14

    User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille (plinth strip/base fascia) warning ! Disconnect electrical current to the unit before removing the gri...

  • Page 15

    User guide drawers 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service drawers checking drawer alignment the unit’s drawers are aligned at the factory before shipment. However, their alignment could have been disturbed during shipment or during overlay p...

  • Page 16

    User guide drawers 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-to-side adjustment the drawer will need a side- to-side adjustment if, when viewed from the top, the drawer front is not square with the sides of the cabinet. This is caused by o...

  • Page 17

    User guide drawers 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service severe adjustment: note: the slides have extra mounting holes that may be used. 1. Loosen one slide’s rear mounting screws. 2. Remove the slide’s front mounting screws. 3. Reposition ...

  • Page 18

    User guide drawers 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service re-installation of drawer caution ! Use care when handling the drawer. Drawer edges, drawer rail and the unit’s slide may be sharp. 1. Set the drawer’s rails onto the slides. 2. Re-in...

  • Page 19

    User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends allowing the unit to run overnight before loading with pro...

  • Page 20

    User guide control operation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation your unit is equipped with two zones. Each zone can be set to a different mode. Control function guide function command display/options off press and hold ...

  • Page 21

    User guide control operation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service u-select ® control digital display the 3000 series units are controlled by a feature rich, advanced oled display control unit. The control panel allows adjustment to tempera...

  • Page 22

    User guide control operation 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service the following table lists modes which include the quick chill feature and the time which quick chill will run. To initiate quick chill: 1. Press to select the desired zone, ...

  • Page 23

    User guide control operation 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service error notification the 3000 model series continuously monitors a series of inputs and parameters to ensure proper and efficient operation of your unit. Should the system det...

  • Page 24

    User guide control operation 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service energy saver mode energy saver mode reduces overall energy consumption by altering user set point, differential, lighting and tone settings. When in energy saver mode a smal...

  • Page 25

    User guide control operation 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service 2. Press . The current setting will begin to flash. 3. Press or to select a different level. 4. Press to confirm your choice. Fahrenheit/celsius temperature and set point in...

  • Page 26

    User guide sabbath mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service l sabbath mode this unit offers a sabbath mode for users who require this functionality during sabbaths. Sabbath mode disables system responses to user initiated activities and a...

  • Page 27

    User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning stainless models stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your ...

  • Page 28

    User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service notice the drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flo...

  • Page 29

    User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the con...

  • Page 30

    User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use storage, vacation and moving if not using the unit for an extended period, or otherwise stored, follow these steps completely: warning ! Electrical shock haz...

  • Page 31

    User guide accessories 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service accessories 80-33027-01 accessories - slide and divide bin organizer, 24" us$109.00

  • Page 32

    User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...

  • Page 33

    User guide troubleshooting 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service checking product temperature to check the actual product temperature in the unit: 1. Partially fill a plastic (nonbreakable) bottle with water. 2. Insert an accurate thermomet...

  • Page 34

    User guide warranty 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty u-line corporation limited warranty 1. U-line corporation (“u-line”) warrants each u-line product to be free from defects in materials and workmanship for a period of one ye...

  • Page 35

    User guide warranty 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 7. If a product defect is discovered during the applicable warranty period, you must promptly notify either u-line at 8900 n. 55th street, milwaukee, wisconsin 53223 usa or at +1.800...