USER GUIDE
Drawers 4
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
RE-INSTALLATION OF DRAWER
CAUTION
!
Use care when handling the drawer. Drawer
edges, drawer rail and the unit’s slide may be
sharp.
1. Set the drawer’s rails onto the slides.
2. Re-install the rails’ mounting screws.
3. Plug in the drawer’s connection wiring (top drawer
only).
Summary of 3024DWR
Page 1
User guide safety • installation & integration • operating instructions • maintenance • service modular 3000 series • 3024dwr • 24" refrigerator drawers right product. Right place. Right temperature. Since 1962..
Page 2
User guide u-line.Com contents safety • installation & integration • operating instructions • maintenance • service intro safety safety and warning disposal installation environmental requirements electrical cutout dimensions product dimensions anti-tip bracket general installation integrated grille...
Page 3
User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, d...
Page 4
User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow...
Page 5
User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...
Page 6
User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this unit is designed to operate between 50°f (10°c) and 100°f (37°c). High ambient temperatures (100°f [37°c] or higher) may reduce the ...
Page 7
User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...
Page 8
User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space ...
Page 9
User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 33-11/16" to 34-11/16" (856 mm to 881mm) 3-5/8" to 4 5/8" (92 to 118 mm) 23 5/8" (600 mm) not including handle 23-7/16" (590 mm).
Page 10
User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket caution ! The anti-tip bracket must be installed to prevent the unit from tipping when doors are fully opened or excess weight is placed on the front of the ...
Page 11
User guide anti-tip bracket 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 5. Using a 3/32" drill bit, drill 3 pilot holes 5/8" (16 mm) deep into cabinetry frame using the anti-tip bracket as a template. 6. Install the 3 remaining #8x5/8" screws int...
Page 12
User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation leveling information 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not...
Page 13
User guide integrated grille - plinth dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated grille - plinth dimensions prepare and install integrated grille (plinth strip/base fascia) 1. Use the dimensions provided in the diagram to c...
Page 14
User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille (plinth strip/base fascia) warning ! Disconnect electrical current to the unit before removing the gri...
Page 15
User guide drawers 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service drawers checking drawer alignment the unit’s drawers are aligned at the factory before shipment. However, their alignment could have been disturbed during shipment or during overlay p...
Page 16
User guide drawers 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-to-side adjustment the drawer will need a side- to-side adjustment if, when viewed from the top, the drawer front is not square with the sides of the cabinet. This is caused by o...
Page 17
User guide drawers 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service severe adjustment: note: the slides have extra mounting holes that may be used. 1. Loosen one slide’s rear mounting screws. 2. Remove the slide’s front mounting screws. 3. Reposition ...
Page 18
User guide drawers 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service re-installation of drawer caution ! Use care when handling the drawer. Drawer edges, drawer rail and the unit’s slide may be sharp. 1. Set the drawer’s rails onto the slides. 2. Re-in...
Page 19
User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends allowing the unit to run overnight before loading with pro...
Page 20
User guide control operation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation your unit is equipped with two zones. Each zone can be set to a different mode. Control function guide function command display/options off press and hold ...
Page 21
User guide control operation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service u-select ® control digital display the 3000 series units are controlled by a feature rich, advanced oled display control unit. The control panel allows adjustment to tempera...
Page 22
User guide control operation 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service the following table lists modes which include the quick chill feature and the time which quick chill will run. To initiate quick chill: 1. Press to select the desired zone, ...
Page 23
User guide control operation 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service error notification the 3000 model series continuously monitors a series of inputs and parameters to ensure proper and efficient operation of your unit. Should the system det...
Page 24
User guide control operation 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service energy saver mode energy saver mode reduces overall energy consumption by altering user set point, differential, lighting and tone settings. When in energy saver mode a smal...
Page 25
User guide control operation 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service 2. Press . The current setting will begin to flash. 3. Press or to select a different level. 4. Press to confirm your choice. Fahrenheit/celsius temperature and set point in...
Page 26
User guide sabbath mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service l sabbath mode this unit offers a sabbath mode for users who require this functionality during sabbaths. Sabbath mode disables system responses to user initiated activities and a...
Page 27
User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning stainless models stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach. Keep your ...
Page 28
User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service notice the drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flo...
Page 29
User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille (plinth strip/base fascia) free of dust and lint, and clean the con...
Page 30
User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use storage, vacation and moving if not using the unit for an extended period, or otherwise stored, follow these steps completely: warning ! Electrical shock haz...
Page 31
User guide accessories 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service accessories 80-33027-01 accessories - slide and divide bin organizer, 24" us$109.00
Page 32
User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...
Page 33
User guide troubleshooting 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service checking product temperature to check the actual product temperature in the unit: 1. Partially fill a plastic (nonbreakable) bottle with water. 2. Insert an accurate thermomet...
Page 34
User guide warranty 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty u-line corporation limited warranty 1. U-line corporation (“u-line”) warrants each u-line product to be free from defects in materials and workmanship for a period of one ye...
Page 35
User guide warranty 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 7. If a product defect is discovered during the applicable warranty period, you must promptly notify either u-line at 8900 n. 55th street, milwaukee, wisconsin 53223 usa or at +1.800...