U-Line CLR1215 Quick Start Manual

Other manuals for CLR1215: User Manual, User Manual, User Manual, Quick Start Manual
Manual is about: 15" clear ice maker

Summary of CLR1215

  • Page 1

    Quick start guide 1000 series • clr1215 • 115 v / 60 hz.

  • Page 2

    Quick start guide u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, deliverin...

  • Page 3

    Quick start guide u-line.Com contents 1 model list 2 safety and warning 2 environmental requirements 3 electrical 3 water hookup 6 drain 8 door swing 8 general installation 9 integrated panel installation 11 control operation 11 first use 11 ice 13 sabbath mode 13 warranty.

  • Page 4

    Quick start guide 1 u-line.Com model list this guide provides the basics to get you started. Looking for more information? Visit u-line.Com to view detailed user guides for all u-line products. Clear ice u-clr1215s-00a u-clr1215s-40a u-clr1215int-00a u-clr1215int-40a u-clr1215b-00a u-clr1215b-40a u-...

  • Page 5

    Quick start guide 2 u-line.Com safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide: safety alert definitions thro...

  • Page 6

    Quick start guide 3 u-line.Com electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. ...

  • Page 7

    Quick start guide 4 u-line.Com caution ! Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home. Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubbe...

  • Page 8

    Quick start guide 5 u-line.Com warning ! Prior to installation, determine if this product contains a gravity style drain or factory installed drain pump. Products without a drain pump may only use a gravity style drain. Failure to connect water supply or drain line connections properly may result in...

  • Page 9

    Quick start guide 6 u-line.Com 4. On the back panel, break away filler feature in bushing with flat screwdriver. 5. Thread water line through back panel hole (with bushing). 6. Turn on water supply and check for leaks. 7. Reinstall back panel and grille/front access panel. 8. Install retaining clip....

  • Page 10

    Quick start guide 7 u-line.Com gravity drain a gravity drain may be used if: drain line has at least a 1" drop per 48" (approximately 2 cm drop per 100 cm) of run. Drain line does not create traps and is vented per local code. 1. Cut the pre-installed drain tube to length. 2. Connect to your local p...

  • Page 11

    Quick start guide 8 u-line.Com notice the maximum lift for the p60 drain pump is 10 feet. This must be done as close to the rear of the unit as possible. Door swing units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless steel and black and white models r...

  • Page 12

    Quick start guide 9 u-line.Com installation 1. Plug in the power/electrical cord. 2. Gently push the unit into position. Be careful not to entangle the cord or water and drain lines. 3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top surface...

  • Page 13

    Quick start guide 10 u-line.Com 9. Using a phillips screwdriver, place one screw into each of the 6 pilot holes and screw down. Do not overtighten screws. 10.Be sure the screws force their way past the opening on the gasket channel and sit flush against the bottom of the channel. 11.Remove clamps fr...

  • Page 14

    Quick start guide 11 u-line.Com control operation first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge ...

  • Page 15

    Quick start guide 12 u-line.Com depth. A fuller cube with less of a dimple results in a thicker ice bridge. As the ice bridge becomes thicker, the tendency for the cubes to stay together as a slab increases. A bridge thicker than 1/8" (3.2 mm) may cause cubes to overfill the ice bucket. Ice thicknes...

  • Page 16

    Quick start guide 13 u-line.Com l sabbath mode u-line clear ice machine models are star-k certified and can be used during the sabbath. View a full list of star-k certified u-line units at www.Star-k.Org. To prepare the unit for the sabbath: 1. Press and hold the until the unit turns off. 2. No new ...

  • Page 17

    Quick start guide 14 u-line.Com 3. The warranty listed above does not apply to floor display models. The warranty for these models shall be 30 days from the date of retail purchase and only if u-line’s product registration card included with the unit is completed and mailed back or electronically su...