V-Tec DT601 User Manual - page 14
-14-
9. Precaustions
10. Specifications
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If
necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad
directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture..
• Payattentiontothehighvoltageinsidetheproducts,pleasereferserviceonlytoatrainedandqualified
professional.
• Power Supply :
DC 24V ;
• Power Consumption:
Standby 40mA; Working status 160mA;
• Camera:
Color CMOS, 2.0 Mega pixel
• 1/2.7’’fisheyecamera,170
0
wide angle;
• Unlocking
time:
1~99s
• Lock Power supply:
12Vdc, 280mA(Internal Power);
• Number of relay circuits:
2(the second lock need external device to support)
• Mounting:
Surface mounting(DT601/ID/FE)
• Flush mounting (DT601F/ID/FE)
• Working temperature:
-15ºC ~ +55ºC
• Dimension:
182(H)×93(W)×44(D)mm(DT601/ID/FE)
• 220(H)×120(W)×50(D)mm(DT601F/ID/FE)