V-tech DT601FE/KP User Manual - page 18
-
15
-
7.Unlock Operations
When the registered user code has been input using the keypad (1~12 digits), the LED background
indicator lights up, the buzzer sounds,and the electric door strike is unlocked.(note that you should
press "#" button(if "#" button is set to confirm button) after input the unlock code)
• The time interval during which the button must be pressed is approximately 10 seconds. If the
time interval exceeds approximately 10 seconds, the input value will be cleared.
• If you make a mistake when inputting the user code,press the" cancel" button and input the user
code again.
• The release function is forbidden and the input operation is disabled for 60 seconds if 10 times
incorrect access codes are continuously attempted. During this time,the buzzer will continuously
sound about 8 times.
Unlocking of user code
1. During calling,pressing "cancel" button can cancel the calling
2. If input the incorrect access code,the buzzer will sound of beep,beep,beep
9.Specifications
8. Precaustions
• Power Supply :
DC 24V ;
• Power Consumption:
Standby 40mA; Working status 160mA;
• Camera:
Color ARS; 420 TV Lines;
• Unlocking
time:
1~99s
• Lock Power supply:
12Vdc, 280mA(Internal Power);
• Number of relay circuits:
2(the second lock need external device to support)
• Mounting:
Flush mounting
• Working temperature:
-15ºC ~ +55ºC
• Dimension:
220(H)×120(W)×50(D)mm
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If
necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad directly.
Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture..
• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified