    User's guide vaisala humidity and temperature probes hmp60 and hmp110 series m211060en-g.

  • Page 2

    Published by vaisala oyj street address: vanha nurmijärventie 21, fi-01670 vantaa, finland mailing address: p.O. Box 26, fi-00421 helsinki, finland phone: +358 9 8949 1 fax: +358 9 8949 2227 visit our internet pages at www.Vaisala.Com © vaisala 2016 no part of this manual may be reproduced, publishe...

  • Page 3: Table Of Contents

    _________________________________________________________________________________ vaisala _________________________________________________________________________ 1 table of contents chapter 1 general information ............................................................................ 5 about t...

  • Page 4

    User's guide _______________________________________________________________________ 2 ____________________________________________________________________ m211060en-g operation ................................................................................................. 29 getting started ........

  • Page 5

    _________________________________________________________________________________ vaisala _________________________________________________________________________ 3 adjustment procedure using serial line (hmp110, hmp110d and hmp113) ......................................................... 56 one-p...

  • Page 6: List Of Figures

    User's guide _______________________________________________________________________ 4 ____________________________________________________________________ m211060en-g list of figures figure 1 hmp60 and hmp110 series probes ........................................ 11 figure 2 filters for hmp60, hmp1...

  • Page 7: General Information

    Chapter 1 _________________________________________________________ general information vaisala _________________________________________________________________________ 5 chapter 1 general information this chapter provides general notes for the manual and the hmp60 and hmp110 series probes. About t...

  • Page 8: Version Information

    User's guide _______________________________________________________________________ 6 ____________________________________________________________________ m211060en-g version information table 1 manual revisions manual code description m211060en-g january 2016. This manual. Modbus protocol added. U...

  • Page 9: Caution

    Chapter 1 _________________________________________________________ general information vaisala _________________________________________________________________________ 7 caution caution warns you of a potential hazard. If you do not read and follow instructions carefully at this point, the product...

  • Page 10: Recycling

    User's guide _______________________________________________________________________ 8 ____________________________________________________________________ m211060en-g recycling recycle all applicable material. Do not dispose of with regular household refuse. Regulatory compliances hmp60 and hmp110 ...

  • Page 11: Trademarks

    Chapter 1 _________________________________________________________ general information vaisala _________________________________________________________________________ 9 trademarks vaisala intercap ® and vaisala humicap ® are registered trademarks of vaisala oyj. Windows® is a registered trademark...

  • Page 12: Product Overview

    User's guide _______________________________________________________________________ 10 ___________________________________________________________________ m211060en-g chapter 2 product overview this chapter introduces the features and options of the hmp60 and hmp110 series probes. Introduction to h...

  • Page 13

    Chapter 2 ___________________________________________________________ product overview vaisala ________________________________________________________________________ 11 1210-009 figure 1 hmp60 and hmp110 series probes no. Model description 1 hmp60 ip65 rated stainless steel probe with intercap® se...

  • Page 14

    User's guide _______________________________________________________________________ 12 ___________________________________________________________________ m211060en-g basic features and options - analog and digital output options: - hmp60, hmp63, hmp110 and hmp113 analog output mode: two analog out...

  • Page 15: Filter Options

    Chapter 2 ___________________________________________________________ product overview vaisala ________________________________________________________________________ 13 filter options for order codes, see section options and accessories on page 72. 1001-008 figure 2 filters for hmp60, hmp110, hmp1...

  • Page 16: Probe Mounting Clamp

    User's guide _______________________________________________________________________ 14 ___________________________________________________________________ m211060en-g installation accessories (optional) for order codes, see section options and accessories on page 72. Probe mounting clamp the option...

  • Page 17

    Chapter 2 ___________________________________________________________ product overview vaisala ________________________________________________________________________ 15 2. Slide the lower clamp part over to the bottom end of the upper part as shown in figure 6 below. 1209-002 figure 6 sliding the ...

  • Page 18: Probe Mounting Flange

    User's guide _______________________________________________________________________ 16 ___________________________________________________________________ m211060en-g probe mounting flange the probe mounting flange is a silicone flange that can be used to hold the probe in a through-wall installati...

  • Page 19: Hmp110D And Hmp110T

    Chapter 2 ___________________________________________________________ product overview vaisala ________________________________________________________________________ 17 duct installation kit for hmp60, hmp110, hmp110d and hmp110t the duct installation kit includes a plastic pipe with a flange (vai...

  • Page 20: Loop Power Converter

    User's guide _______________________________________________________________________ 18 ___________________________________________________________________ m211060en-g loop power converter the loop power converter is an open frame module that converts one 0 ... 2.5 vdc voltage output to a 4 ... 20 m...

  • Page 21: Cables

    Chapter 2 ___________________________________________________________ product overview vaisala ________________________________________________________________________ 19 cables connection cables have a straight, threaded female m8 connector on one end and open wires on the other end. Also other com...

  • Page 22: Installation

    User's guide _______________________________________________________________________ 20 ___________________________________________________________________ m211060en-g chapter 3 installation this chapter provides you with information that is intended to help you install the hmp60 and hmp110 series p...

  • Page 23

    Chapter 3 ________________________________________________________________ installation vaisala ________________________________________________________________________ 21 dimensions for hmp63 and hmp113 0912-103 figure 16 hmp63 and hmp113 dimensions 0912-102 figure 17 hmp63 and hmp113 with plastic ...

  • Page 24: Hmp110T Probes

    User's guide _______________________________________________________________________ 22 ___________________________________________________________________ m211060en-g mounting the hmp60, hmp110, hmp110d and hmp110t probes hmp60, hmp110, hmp110d and hmp110t are designed to be mounted from the m12 th...

  • Page 25

    Chapter 3 ________________________________________________________________ installation vaisala ________________________________________________________________________ 23 drilling instructions for duct installation kit 0505-178 figure 19 drilling instructions the following numbers refer to figure 1...

  • Page 26: Note

    User's guide _______________________________________________________________________ 24 ___________________________________________________________________ m211060en-g mounting the hmp63 and hmp113 probes hmp63 and hmp113 probes do not have a thread on the probe body. For a convenient installation, ...

  • Page 27: Wiring

    Chapter 3 ________________________________________________________________ installation vaisala ________________________________________________________________________ 25 wiring for a secure connection to the probe, connect to the 4-pin m8 connector using a threaded connector. The grounding method ...

  • Page 28

    User's guide _______________________________________________________________________ 26 ___________________________________________________________________ m211060en-g table 5 pinout of the probe connector pin hmp60 / hmp63 / hmp110 / hmp113 / hmp110t hmp110d / hmp110ref wire color 1 5 ... 28 vdc (v...

  • Page 29

    Chapter 3 ________________________________________________________________ installation vaisala ________________________________________________________________________ 27 wiring with the loop power converter to use the loop power converter module with a hmp60 or hmp110 series probe, make sure that:...

  • Page 30: Power Supply Requirements

    User's guide _______________________________________________________________________ 28 ___________________________________________________________________ m211060en-g power supply requirements the operating voltage for the hmp60 and hmp110 series probes must be in the following range: table 6 opera...

  • Page 31: Operation

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 29 chapter 4 operation this chapter contains information that is needed to operate the hmp60 and hmp110 series probes. Getting starte...

  • Page 32: Note

    User's guide _______________________________________________________________________ 30 ___________________________________________________________________ m211060en-g connecting to the serial interface the connection to the serial interface is via the 4-pin connector on the probe; see connector pin...

  • Page 33

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 31 for a description of the modes and the smode command that is used to change the mode, see section set serial interface mode on pag...

  • Page 34: Probes

    User's guide _______________________________________________________________________ 32 ___________________________________________________________________ m211060en-g terminal application settings for digital probes the steps below describe how to connect to digital probes using the putty terminal ...

  • Page 35

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 33 0807-004 figure 23 putty terminal application.

  • Page 36: Modbus Mode

    User's guide _______________________________________________________________________ 34 ___________________________________________________________________ m211060en-g accessing serial line command interface (rs-485 mode) from analog or modbus mode follow the steps below to connect to the serial lin...

  • Page 37: Modbus Communication

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 35 modbus communication the modbus variant used in hmp60 and hmp110 series probes is modbus rtu. For a list of the available modbus r...

  • Page 38: List Of Serial Commands

    User's guide _______________________________________________________________________ 36 ___________________________________________________________________ m211060en-g list of serial commands all commands can be issued either in uppercase or lowercase. In the command examples, the keyboard input by ...

  • Page 39: View Device Information

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 37 table 11 additional commands for probes with rs-485 output command description ?? Output information about the device in poll mode...

  • Page 40: View Order Code

    User's guide _______________________________________________________________________ 38 ___________________________________________________________________ m211060en-g view calibration information use the cdate command to view the calibration date and ctext to view the calibration info text. Date fo...

  • Page 41: View Serial Number

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 39 view serial number use the snum command to view the serial number of the probe. Snum example: snum serial number : h3640004 view s...

  • Page 42: Stop Measurement Output

    User's guide _______________________________________________________________________ 40 ___________________________________________________________________ m211060en-g outputting the results continues in intervals issued with the command intv . You can stop the output by entering the s command. Stop...

  • Page 43: Set Serial Interface Mode

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 41 example (shows default settings): seri baud p d s : 19200 n 8 1 set serial interface mode use the smode command to set the operati...

  • Page 44: Note

    User's guide _______________________________________________________________________ 42 ___________________________________________________________________ m211060en-g note in the run mode, the probe may send the measurement data message right as you are typing the s command to stop the sending. The...

  • Page 45: Set Probe Address

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 43 set probe address use the addr command to view or set the probe address. To operate in the poll mode, the probe must have an addre...

  • Page 46: Set Measurement Units

    User's guide _______________________________________________________________________ 44 ___________________________________________________________________ m211060en-g set measurement units use the unit command to view or set the measurement units that are used in the serial line measurement message...

  • Page 47: Calibration Commands

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 45 calibration commands calibrate humidity measurement use the crh command to perform a one-point or two-point correction to the capa...

  • Page 48

    User's guide _______________________________________________________________________ 46 ___________________________________________________________________ m211060en-g clear adjustment of rh measurement use the crhclr command to clear the adjustment of rh measurement that has been done using the crh...

  • Page 49

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 47 clear adjustment of t measurement use the ctclr command to clear the adjustment of temperature measurement that has been done usin...

  • Page 50: Other Commands

    User's guide _______________________________________________________________________ 48 ___________________________________________________________________ m211060en-g other commands set analog output mode use the amode command to show or set the operation mode of the analog output. This command is ...

  • Page 51: Scaling

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 49 set analog output parameters and scaling use the asel command to show or set the output parameters and scaling of the analog outpu...

  • Page 52: Note

    User's guide _______________________________________________________________________ 50 ___________________________________________________________________ m211060en-g set analog output error indication level if the device is malfunctioning, the analog output is set to a specified level. This overri...

  • Page 53: Extend Maximum Rh Reading

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 51 extend analog output range use the aover command to allow the analog output channels to exceed their specified range by 10%. The s...

  • Page 54: Display Command List

    User's guide _______________________________________________________________________ 52 ___________________________________________________________________ m211060en-g example (on analog output, extend the maximum rh reading to 120% and scale the rh output on channel 2 from (0…1 v) 0...100% to (0…1 ...

  • Page 55: Reset The Probe

    Chapter 4 _________________________________________________________________ operation vaisala ________________________________________________________________________ 53 close the connection in poll mode the close command closes the connection to the probe. Close example: close line closed reset the...

  • Page 56: Maintenance

    User's guide _______________________________________________________________________ 54 ___________________________________________________________________ m211060en-g chapter 5 maintenance this chapter provides information that is needed in basic maintenance of the hmp60 and hmp110 series probes. P...

  • Page 57: Calibration Procedure

    Chapter 5 _______________________________________________________________ maintenance vaisala ________________________________________________________________________ 55 new filters can be ordered from vaisala. For available filters, see section filter options on page 13. The order codes of the filt...

  • Page 58: Note

    User's guide _______________________________________________________________________ 56 ___________________________________________________________________ m211060en-g adjustment procedure using serial line (hmp110, hmp110d and hmp113) note if you are adjusting a probe that is in the analog output m...

  • Page 59: Hmp113)

    Chapter 5 _______________________________________________________________ maintenance vaisala ________________________________________________________________________ 57 - try the ?? Command in case the probe is in poll mode, open the line using open command if necessary. - check your serial line se...

  • Page 60

    User's guide _______________________________________________________________________ 58 ___________________________________________________________________ m211060en-g 4. Wait for 20 – 40 minutes for the humidity to stabilize. 5. Start the terminal session and connect the usb cable to the probe. If ...

  • Page 61: Hmp110T)

    Chapter 5 _______________________________________________________________ maintenance vaisala ________________________________________________________________________ 59 if you wish to remove the effects of rh calibration (returning the rh measurement of the probe to the factory calibrated state), s...

  • Page 62: Note

    User's guide _______________________________________________________________________ 60 ___________________________________________________________________ m211060en-g 8. Use the errs command to see that no errors are active: errs 9. Give the ct command, with the temperature value of the reference a...

  • Page 63: Measurement

    Chapter 5 _______________________________________________________________ maintenance vaisala ________________________________________________________________________ 61 - mi70 indicator. - connection cable for mi70 indicator (219980). - one humidity reference. One-point adjustment with a single off...

  • Page 64

    User's guide _______________________________________________________________________ 62 ___________________________________________________________________ m211060en-g - one known and stable temperature reference. 1. Connect the probe to port i of the mi70 indicator. 2. Turn on the mi70 indicator. 3...

  • Page 65: Repair Maintenance

    Chapter 5 _______________________________________________________________ maintenance vaisala ________________________________________________________________________ 63 repair maintenance changing the intercap® sensor (hmp60 and hmp63) this procedure restores the humidity measurement accuracy of th...

  • Page 66: Note

    User's guide _______________________________________________________________________ 64 ___________________________________________________________________ m211060en-g changing the humicap® 180r sensor (hmp110, hmp110d and hmp113) note replacing the humidity sensor of the hmp110, hmp110d and hmp113 ...

  • Page 67: Troubleshooting

    Chapter 6 ____________________________________________________________ troubleshooting vaisala ________________________________________________________________________ 65 chapter 6 troubleshooting this chapter describes common problems, their probable causes and remedies, and contact information for...

  • Page 68: Technical Support

    User's guide _______________________________________________________________________ 66 ___________________________________________________________________ m211060en-g problem or message likely causes and solutions the probe is not responding to any serial commands. - disconnect the usb cable from t...

  • Page 69: Technical Data

    Chapter 7 _____________________________________________________________ technical data vaisala ________________________________________________________________________ 67 chapter 7 technical data this chapter provides the technical data of the hmp60 and hmp110 series probes. Specifications performan...

  • Page 70: Relative Humidity

    User's guide _______________________________________________________________________ 68 ___________________________________________________________________ m211060en-g performance (hmp110 and hmp110d) relative humidity measurement range 0 ... 100 %rh accuracy (incl. Non-linearity, hysteresis and rep...

  • Page 71: Performance (Hmp113)

    Chapter 7 _____________________________________________________________ technical data vaisala ________________________________________________________________________ 69 performance (hmp113) relative humidity measurement range 0 ... 100 %rh accuracy (incl. Non-linearity, hysteresis and repeatabilit...

  • Page 72: Operating Environment

    User's guide _______________________________________________________________________ 70 ___________________________________________________________________ m211060en-g operating environment operating temperature range hmp60 -40 ... +60 °c hmp63 -40 ... +60 °c hmp110 -40 ... +80 °c hmp113 -40 ... +60...

  • Page 73: And Hmp110T)

    Chapter 7 _____________________________________________________________ technical data vaisala ________________________________________________________________________ 71 external loads 0 ... 1 r l min 10 k Ω 0 ... 2.5 / 0 ... 5 / 1 ... 5 v r l min 50 k Ω mechanics (hmp60, hmp110, hmp110d and hmp110...

  • Page 74: Options And Accessories

    User's guide _______________________________________________________________________ 72 ___________________________________________________________________ m211060en-g options and accessories information on spare parts, accessories, and calibration products is available online at www.Vaisala.Com and...

  • Page 75: Modbus Reference

    Appendix a _________________________________________________________ modbus reference vaisala ________________________________________________________________________ 73 appendix a modbus reference this appendix describes the modbus protocol implementation of the hmp60/hmp110 series probes. For info...

  • Page 76: Modbus Register Map

    User's guide _______________________________________________________________________ 74 ___________________________________________________________________ m211060en-g modbus register map table 17 modbus register map (measurement values and settings) logical address (decimal) pdu address (hexadecima...

  • Page 77: Note

    Appendix a _________________________________________________________ modbus reference vaisala ________________________________________________________________________ 75 pdu address actual address bytes used in a modbus protocol data unit. Lsw least significant word (bits 15 … 0). Msw most significa...

  • Page 78: Note

    User's guide _______________________________________________________________________ 76 ___________________________________________________________________ m211060en-g device identification objects table 18 device identification objects object id (decimal) object id (hexadecimal) object name (as def...

  • Page 79