Valcom V-2901A User Manual

Other manuals for V-2901A: Datasheet
Manual is about: UNIVERSAL DOOR ANSWERING SYSTEM

Summary of V-2901A

  • Page 1

    Vsp-v-2901a issue 4 1 947301a v-2901a universal door answering system introduction the v-2901a, universal door answering system, when used with valcom doorplate speakers, provides voice paging with handsfree reply to a door from any telephone location. The v-2901a initiates ring-in on the telephone ...

  • Page 2

    2 features • compatible with pabx, e-key and 1a2 telephone systems • switch selectable - loop or ground start access • provides handsfree talkback • rj11 modular connector for tip and ring connections • power on led • provides door unlock contacts • programmable options: programming access code ring...

  • Page 3

    3 * a single line telephone cannot be connected to both the v-2901a and an incoming central office line. ** it is recommended that one talkback speaker be used. Use of more than one talkback speaker may result in damage to the v-2901a. Up to 40 one-way amplified speakers may be connected to the v-29...

  • Page 4

    4 ___ 4. If using a door button with the talkback speaker, connect normally open, single pole push-button switch to door button connection pin 33 (r/g) and pin 9 (br/r) ground. (figure 5 depicts the speaker/door button hookup). ___ 5. Move slide switch sw1 (located on the v-2901a board) to the on po...

  • Page 5

    5 26 1 27 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 w/bl bl/w w/o o/w w/gr gr/w w/br br/w w/s s/w r/bl bl/r r/o o/r r/g g/r r/br br/r r/s s/r bk/bl bl/bk bk/o o/bk bk/g g/bk bk/br br/bk bk/s s/bk y/bl bl/y y/o...

  • Page 6

    6 phone to speaker music gnd start loop start sw2 off on speaker to phone ringer sw1 rj11 power led figure 3 - connector and control locations v-2901a vpb-260 figure 4 - battery backup typical applications handsfree speaker tip handsfree speaker ring door button ground (r/o) (o/r) (r/g) (br/r) p 32 ...

  • Page 7

    7 typical applications (continued) remote ground (g/r) p 8 (br/r) p 9 momentary single pole, n. O. Single throw switch 66 block equipment customer provided figure 7 - remote/confirmation pushbutton for manual door release station ground (bl/r) p 6 (br/r) p 9 66 block equipment customer provided - + ...

  • Page 8

    8 volume adjustments there are four volume controls on the v-2901a. See figure 3 for location of these controls. ___ 1. Phone to speaker: adjusts speaker volume. ___ 2. Speaker to phone: adjusts talkback volume from the speaker. Important: set this volume at the lowest practical level. Setting this ...

  • Page 9

    9 activate lock relay (door unlock) this code would be used to operate the door unlock contacts which can be used to open an electric lock used at a doorway or gate. The default access code to activate the lock relay is *. This code can be from 1 to 7 digits and the asterisk (*) sign can be programm...

  • Page 10

    10 to enable the door alarm after it has been disabled: 1. Lift handset, press # to receive dial tone. 2. Press 6. 3. Receive dial tone. Alert tone the phone and station receives a ringback tone prior to connection. Default the station receives the tone. To remove the alert tone: 1. Lift handset, pr...

  • Page 11

    11 technical assistance when trouble is reported, make certain there are no broken connections leading to this system. Table 1 identifies some possible problems with solutions. Assistance in troubleshooting is available from the factory. When calling, you should have a vom and a telephone test set a...

  • Page 12

    12 program chart record and file in a secure place function default reprogram parameter new program master access code (mac) 1 2 3 # # # # 1 2 3 * * *______* * * 7 digits excluding # and * ring pattern american ring british ring dutch ring american ring # # mac * 5 # # mac * 6 # # mac * # activate l...