Valcom V-2901A User Manual - page 9
9
Activate Lock Relay (Door Unlock)
This code would be used to operate the door unlock
contacts which can be used to open an electric lock
used at a doorway or gate. The default access code to
activate the lock relay is *. This code can be from 1
to 7 digits and the asterisk (*) sign can be
programmed in this code if desired.
To change this code:
1. Lift handset, dial # to hear dial tone.
2. Press # 1 2 3 # on the dialpad.
3. Press 1.
4. Enter up to 7 digits.
5. Press #.
6. Receive dial tone.
Duration of Lock Relay Activation
This function determines the length of time the lock
relay remains activated after dialing the door unlock
code. The default equals two seconds. The length of
time the lock relay remains activated can be from one
to 99 seconds depending on the specific situation.
However, once an opening and closing of a door
takes place, the unlock relay will release prior to the
expiration of the programmed period preventing
further entries.
To change this default setting:
1. Lift handset, dial # to hear dial tone.
2. Press # 1 2 3 # 6 on the dialpad.
3. Enter the number of seconds the lock should
remain activated (1-99).
4. Press #.
5. Receive dial tone.
Time Door May Remain Open after
Unlock before Alarm
(this period of time
also sets the exit delay time)
The length of time the door or gate should remain
open will vary depending on the actual application.
A drive-through gate may require a longer time than a
walk-through door. If, for some reason, the opening
does not close by the designated period of time, an
alarm condition will occur (see Operation). The
possible programmed time for a door to remain open
can be from 0 to 999 seconds. The default for this
function is 15 seconds. This default is changed by:
1. Lift handset, press # to hear dial tone.
2. Press # 1 2 3 # 7 on the dial pad.
3. Enter the number of seconds the door should
remain open (0-999).
4. Press #.
5. Hear dial tone.
Entry Delay Time
If a key entry occurs at the door (an entry not using
the dialpad or remote button), the remote button must
be pressed or the confirmation code must be dialed on
the telephone keypad within a designated period of
time after the door is opened, signifying a legitimate
door opening, or the V-2901A will go into alarm
mode. The default time for the confirmation press is
15 seconds. This time can be changed by:
1. Lift handset, press # to hear dial tone.
2. Press # 1 2 3 # 8.
3. Enter time length in seconds (0-999).
4. Press #.
5. Receive dial tone.
Duration of Ring
When the door button is pressed, it activates the
phone into a ring cycle. The ring cycle will continue
for a programmed duration and stop if unanswered.
The default equals 30 seconds. To change this
default:
1. Lift handset, press # receive dial tone.
2. Press # 1 2 3 # 5.
3. Enter the duration of ringing desired
(1 - 255 seconds; 0 = continuous).
4. Press #.
5. Receive dial tone.
Disable Station Alarm
On power up, the station alarm condition is active. In
the event a doorway or gate would need to be left
open for an extended time (or at least longer than the
programmed time it can remain open before an alarm
condition), the alarm can be disabled.
To leave door open without causing an alarm
condition:
1. Lift handset, press # and receive dial tone.
2. Press 5.
3. Enter disable code (default is *; this may have
been changed - see below).
4. Receive dial tone.
The default code for disabling the station alarm
condition is *. To changethis default:
1. Lift handset, press # and hear dial tone.
2. Press # 1 2 3 *.
3. Enter up to 7 digits.
4. Press #.
5. Receive dial tone.
NOTE: When the station is disabled and then
accessed, the alert tone will be at a lower pitch as
a reminder that the station alarm has been
disabled.