Valdorf GT8600G Installation And Operation Manual - page 5
3
Specifications
Model Numbers covered in this Specification
GT[1]8600G
Gas Griddle Toaster
NOTE:
[1]: - Model Options;
- -
Standard.
L
- Low Back.
B
- Bold Front.
LB
- Low Back and Bold Front.
General
A commercial heavy-duty gas fired griddle toaster, having two tubular burners heating a griddle
plate from underneath and providing toasting heat for the toasting rack below.
Burners are operated by individual control valves and are provided with a piezo ignition and a
permanent pilot incorporating a thermocouple flame failure control.
Optional Accessories
This appliance can be fitted with the following optional accessories, (refer to 'Replacement Parts List'
for details).
Plinth Kit.
Gas Supply Requirements
- Australia:
- New Zealand:
NOTE:
* - Measure burner operating pressure at manifold test point with both burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
Natural Gas
LP Gas (Propane)
Input Rating (N.H.G.C.)
42 MJ/hr
Supply Pressure
1.13 - 3.40
kPa
2.75 - 4.50 kPa
Burner Operating Pressure
1.00 kPa (*)
2.50 kPa (*)
Gas Connection
1
/
2
” BSP Male
42 MJ/hr
Natural Gas
LP Gas
Input Rating (N.H.G.C.)
42 MJ/hr
Supply Pressure
1.13 - 3.40
kPa
2.75 - 4.50 kPa
Burner Operating Pressure
1.00 kPa (*)
2.50 kPa (*)
Gas Connection
1
/
2
” BSP Male
42 MJ/hr