Valor 534XAP Installation And Owner's Manual

Manual is about: Direct Vent Gas Fireplace Heater

Summary of 534XAP

  • Page 1

    Installer: leave this manual with the appliance. Consumer: retain this manual for future reference. Direct vent gas fireplace heater model 534 xan (natural gas) model 534xap (propane) manufactured by miles industries ltd. British columbia, canada 4000307-10 - do not store or use gasoline or other fl...

  • Page 2

    2 contents 1. Safety information ........................................................................................................................................................................ 3 2. Options.........................................................................................

  • Page 3

    3 1. Safety information warning: do not operate the appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person. (the whole window unit may be temporarily removed by the owner for cleaning the interior of the firebox, ...

  • Page 4

    4 state of california. Proposition 65 warning. Fuels used in gas, wood-burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the state of california to cause cancer, birth defects and other reproductive harm. California health & safety code sec. 25...

  • Page 5

    5 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system. (d) manufacturer requirements - gas equipment venting system not provided. When the manufacturer of a product a...

  • Page 6

    6 2. Options heater engine unit #534xan is used with all natural gas installations. Heater engine unit #534xap is used with all propane installations. 2.1 optional features circulating fan having variable speeds and temperature control, it is designed to boost the natural convection process through ...

  • Page 7

    7 mantle depth “a” 1” (25mm) 2” (51mm) 3” (76mm) 4”-5” (102mm- 127mm) 6” (152mm) 7” (178mm) 8”–12” (203mm-305mm) max. Mantle clearance “b” 7” (178mm) 8” (203mm) 9” (229mm) 10” (254mm) 11” (279mm) 12” (305mm) 14” (356mm) figure 1 major dimensions & clearances without optional trims (shown with #601sf...

  • Page 8

    8 3. General 3.1 approvals & codes these appliances are certified by c.S.A. For use in canada and the usa. These appliances are for installation directly venting through an outside wall or through the roof. Model 534xan is for use with natural gas. Model 534xap is for use with propane. It can be con...

  • Page 9

    9 4. Location 4.1 framing the framing dimensions are shown in figure 4. • a non-combustible hearth is not necessary in front of this appliance. • note that the unit is installed at the framing stage and fixed to framing using support angles (see figures 27 and 31). Wall finish is then installed over...

  • Page 10

    10 graph 1 4.4 rear vent connection, vertical vent rise with horizontal rear termination see figure 7. Can be used with either #551dvk standard vent kit or another terminal cap and accessories. Adapter #817vak, two 90° vent elbows and pipe lengths will be required. (see venting options section of th...

  • Page 11

    11 4.6 corner location, rear vent connection, horizontal vent run only see figure 8. Can be used with either #551dvk standard vent kit or another terminal cap and accessories. Adapter #817vak and 45º elbow will be required. (see venting options section of this manual.) 4.7corner location, rear vent ...

  • Page 12

    12 4.9 rear vent connection, vertical rise with offset, through the roof termination see figure 11. For situations where offset is necessary in an attic to avoid obstructions or allow useful space. Adapter #817vak, one 90º vent elbow, two 45º vent elbows, pipe lengths, a vertical vent terminal and r...

  • Page 13

    13 figure 12 4.10 top vent connection, horizontal rear termination see figure 12. Can be used with either #551dvk standard vent kit or another terminal cap and accessories. Adapter #817vak, one 90° vent elbow and pipe lengths will be required. (see venting options section of this manual). The locati...

  • Page 14

    14 4.11 top vent connection, horizontal side termination the vent pipe dimensional requirements in section 4.10 apply. The minimum floor location is shown in figure 14. Can be used with either #551dvk standard vent kit or another terminal cap and accessories. Adapter #817vak, one 90° vent elbow and ...

  • Page 15

    15 4.14 top vent connection, through the roof termination* see figure 16. Adapter #817vak, pipe lengths, a vertical vent terminal, and roof flashing will be required. Various other ceiling or roof items may be necessary depending on the particular installation (see venting options section of this ma...

  • Page 16

    16 4.16 vent location • the vent terminal must be located on an outside wall or through the roof. • this direct vent appliance is designed to operate when an undisturbed airflow hits the outside vent terminal from any direction. • the minimum clearances from this terminal that must be maintained whe...

  • Page 17

    17 5. Supply gas heater engine unit #534xan is used with all natural gas installations. Heater engine unit #534xap is used with all propane installations. The supply pressure must be between the limits shown in section 3.2 of this manual. The supply connection is 3 / 8 ’’npt. The opening for the gas...

  • Page 18

    18.

  • Page 19

    19 7. Appliance preparation 7.1 window removal see figure 20. • turn the top three spring loaded window bolts through 90 0 to release the window from the firebox. • remove the bottom three spring-loaded window bolts. • detach the chain from the top right corner of the window. • carefully lift the wi...

  • Page 20

    20 7.5 top heat shield & stand-off fitting see figures 24 & 25. 1. If installing appliance with top vent outlet remove the plate covering the vent hole in the top heat shield by unscrewing four screws. If installing with rear vent outlet, the plate must remain covering the hole. 2. Remove the screws...

  • Page 21

    21 7.6 support angle fitting see figure 26 the distance from the wall angles to the front face of the heater case is adjustable between 3 / 8 ” (10mm) and 1 3 / 16 ” (30mm) to allow for a range of wall finish material thickness (e.G. Tile etc). 1. Fit the top angle support to the case top with three...

  • Page 22

    22 7.8 attaching rear ceramic support fit the rear ceramic support to the firebox back panel with three screws. See figure 29. 7.9 attaching to the framing 1. Place the heater in position in the framing. 2. Secure the side support angles to the side studding through two holes each side with the wood...

  • Page 23

    23 8. Installations with horizontal termination – installing to wall see section 4 for full range of horizontal termination applications. 8.1 flat on wall installations with valor #551dvk terminal 1. Cut the vent terminal pipe unit to size. See figure 31. Important! The drain hole must be clearly ou...

  • Page 24

    24 8.2 wall opening • where applicable, fit all the required pipes and elbows up to the wall. See the manufacturer’s instructions supplied with the venting sections. • check the wall opening position. • make wall opening. If the wall is constructed of solid non-combustible materials and has no combu...

  • Page 25

    25 9.Installations with through the roof vertical termination • check the roof pitch to determine which roof flashing will be needed - see vent accessories section 2.4. • the distance from the roof to the lowest terminal discharge opening (“h” in figure 35) depends on the roof pitch and must be in a...

  • Page 26

    26 10. Remote control installation caution! Don’t connect the batteries to the remote control receiver until the wires are connected to the burner control unit, as short circuit could result in destruction of the electrical components. When installing the remote please refer to figures 37 and 38 bel...

  • Page 27

    27 11. Gas supply installation & aeration setting 11.1 gas supply installation • the gas supply pipe should enter the appliance case through the opening at the rear left side. The supply pipe should be connected to the appliance gas inlet pipe situated at the left side of the control unit. Supply li...

  • Page 28

    28 figure 44 ash bed 12. Ceramic fuel bed installation 12.1 ceramic walls installation 1. Locate the ceramic rear wall in the channel at back of the firebox and flat against the back of the firebox. See figure 41. 2. Locate the sidewalls against the sides of the firebox. Make sure that they are behi...

  • Page 29

    29 13. Window refitting & checking 1. Refit the window with the bottom three bolts. The bolts should be screwed in securely. 2. Refit the chain to the top right corner of the window. 3. Refit the top three bolts securing by turning them through 90º. 4. Pull the top of the window forward and release ...

  • Page 30

    30 figure 55 side channel installation figure 51 trims & corner plate attachment 15. Front installation 15.1 additional optional 3 or 4 sided trims 1. Slide a corner connection plate into the channels in the top trim and a side trim. Butt the two trims together. Fit four grub screws and tighten to s...

  • Page 31

    31 16. Owners information please read the safety information and notes on page 3. 16.1 operating your fire the operating instructions are also on a chained plate inside the control access door. 1. For your safety, this appliance is fitted with a flame supervision device, which will shut off the gas ...

  • Page 32

    32 16.2 cleaning it will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass and causes dust, lint etc. To cling to the glass surface. Initially paint, while curing, may deposit a slight film on the glass. We therefore recomme...

  • Page 33

    33 16.3 checks • a periodic check of the pilot and burner flames should be made. Check after the fire has been on for at least 30 minutes. The pilot flame must cover the tip of the thermocouple probe. The main burner flame pattern will vary from appliance to appliance depending on the type of instal...

  • Page 34

    34 for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting , follow these instructions exactly. T...

  • Page 35

    35 18. Approved vent suppliers approved alternative vent suppliers for 530, 534, 535 and 739 models venting parts code / availability by manufacturer venting parts description s impso n dur av ent sel kir k se c u r e ve n t rl h indu s t ri e s mil e s indu s t ri e s co-axial kit, 26" long 551dvk ...

  • Page 36

    36 venting parts code / availability by manufacturer venting parts description simp son du raven t se lk ir k secur e ven t rl h industr ies mi les industr ies galvanized 945 black 945b sv4ebr45 galvanized swivel 945g 4dt-el45 sv4e45 dv 4 5 ° e l bow s black swivel 945bg 4dt-el45(b) sv4eb45 galvaniz...

  • Page 37

    37 19. Miles industries ltd. Warranty for valor brand products if you have a problem with this unit, please contact your dealer or supplier immediately. Under no circumstances should you attempt to service the unit in any way by yourself. The warranties in paragraphs 1 and 2 are provided only to the...