Valor 534XAP Installation & operating instructions manual

Manual is about: Direct Vent Gas Fireplace Heater

Summary of 534XAP

  • Page 1

    4000307-13 warning: if the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. What to do if you smell gas • do not try to light the appliance. • do not touch any electrical switch; do not use any phone ...

  • Page 2: Warning

    2 designed and manufactured by / for miles industries ltd. 190 – 2255 dollarton highway, north vancouver b.C., canada. V7h 3b1 tel. (604) 984-3496 fax (604) 984-0246 www.Milesfi replaces.Com © copyright miles industries ltd., 2008 warning hot glass will cause burns. Do not touch glass until cooled. ...

  • Page 3

    33 table of contents safety and warning information ..............................................................4 options .......................................................................................................7 dimensions ...............................................................

  • Page 4

    44 safety and warning information children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Do not place furniture or any ot...

  • Page 5

    55 state of california. Proposition 65 warning. Fuels used in gas, wood-burning or oil fi red appliances, and the products of combustion of such fuels, contain chemicals known to the state of california to cause cancer, birth defects and other reproductive harm. California health & safety code sec. ...

  • Page 6

    66 venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system. (d) manufacturer requirements - gas equipment venting system not provided. When ...

  • Page 7

    77 options heater engine unit #534xan is used with all natural gas installations. Heater engine unit #534xap is used with all propane gas installations. Optional features circulating fan kit #755cfk having variable speed and temperature control, it is designed to boost the natural convection process...

  • Page 8

    88 32-3/16” (817 mm) 29-3/4” (756 mm) 3” (75 mm) min. To side wall from inner frame mantel 36” (914 mm) min. See table a b 23-1/8” (587 mm) to r e ar v e n t c e n ter 33-1/2” (850 mm) 14” (355 mm) 34-7/8” (887 mm) 31-1/8” (780 mm) 34-7/8” (887 mm) 32-1/2” (825 mm) finished wall (see location sectio...

  • Page 9

    99 specifi cations approvals & codes these appliances are certifi ed by ansi z21.88-2007 / csa 2.33-2007 vented gas fireplace heater for use in canada and usa. These appliances are for installation directly venting through an outside wall or through the roof. Model 534xan is for use with natural gas...

  • Page 10

    10 10 location framing the framing dimensions are shown in figure 4. A non-combustible hearth is not necessary in front of this appliance. Note that the unit is installed at the framing stage and fi xed to framing using support angles. See fi gures 26 and 30. Wall fi nish is then installed over the ...

  • Page 11

    11 11 minimum maximum a: from fl oor to top of vent duct 4’-3½” (131 cm) 9’-3½” (283 cm) b: frame front face to outside wall - 12’-5½” (380 cm) c: frame front face to inside wall 2’-5½” (75 cm) - d: vertical pipe run between elbows 12” (30.5 cm) 6’ (183 cm) e 1 +e 2 : total horizontal pipe run inclu...

  • Page 12

    12 12 location rear vent connection—corner location, horizontal vent run only see fi gure 8. Can be used with either #551dvk standard vent kit or another terminal cap and accessories. Adapter #817vak and 45° elbow will be required. See venting accessories list on pages 39–40 for allowable components...

  • Page 13

    13 13 location rear vent connection—vertical rise with offset, through the roof termination see fi gure 11. For situations where offset is necessary in an attic to avoid obstructions or allow useful space. Adapter #817vak, one 90° vent elbow, two 45° vent elbows, pipe lengths, a vertical vent termin...

  • Page 14

    14 14 minimum maximum a: from fl oor to top of vent duct 3’-7 9 ⁄ 16 ” (111 cm) 9’-1 9 ⁄ 16 ” (278 cm) b: frame front face to outside wall - 11’4” (345 cm) c: frame front face to inside wall 16” (40.6 cm) - d: vertical pipe run between elbows 6” (15.2 cm) 6’ (183 cm) e: total horizontal pipe run fro...

  • Page 15

    15 15 top vent connection—horizontal side termination the vent pipe dimensional requirements in section top vent connection—horizontal rear termination apply. The minimum fl oor location is shown in fi gure 14. Can be used with either #551dvk standard vent kit or another terminal cap and accessories...

  • Page 16

    16 16 top vent connection—through the roof termination* see fi gure 16. Adapter #817vak, pipe lengths, a vertical vent terminal and roof fl ashing will be required. Various other ceiling or roof items may be necessary depending on the particular installation. See venting accessories list on pages 39...

  • Page 17

    17 17 rear or top outlet conversion to co-linear liners using valor #556cla co-linear adapter. (generic co-axial to co-linear adapter boxes may also be used as an alternate to the 556cla). Only for use when retrofi tting a solid-fuel burning fi replace and chimney. The appliance must not be connecte...

  • Page 18

    18 18 vent location the vent terminal must be located on an outside wall or through the roof. This direct vent appliance is designed to operate when an undisturbed airfl ow hits the outside vent terminal from any direction. The minimum clearances from this terminal that must be maintained when locat...

  • Page 19

    19 19 supply gas heater engine unit #534xan is used with all natural gas installations. Heater engine unit #534xap is used with all propane gas installations. The supply pressure must be between the limits shown in the section specifi cations of this manual. The supply connection is ⅜” npt. The open...

  • Page 20

    20 20 pack contents ceramic walls ceramic logs gas inlet adaptor stand-off brackets screw pack top heat shield panel type “c” type “b” type “a” ash bed support port cover appliance engine frame side fixing brackets frame top support angle side channels upper louver lower louver hinge spacers magnet ...

  • Page 21

    21 21 appliance preparation window removal see fi gure 20. Turn the top two spring-loaded window bolts through 90° to release the window from the fi rebox. Remove the bottom two spring-loaded window bolts. Detach the chain from the top right corner of the window. Carefully lift the window away. Keep...

  • Page 22

    22 22 appliance preparation #817vak pipe adapter fitting if installing fl at on wall with valor terminal unit #551dvk, ignore this stage. See fi gure 23. Fit the adapter #817vak over the appliance vent collars pushing on fi rmly. For rear vent outlet connection, align the adapter so that the seam on...

  • Page 23

    23 23 appliance preparation top heat shield & stand-offs fitting see fi gures 24 & 25. If installing appliance with top vent outlet, remove the plate covering the vent hole in the top heat shield by unscrewing four screws. If installing with rear vent outlet, the plate must remain, covering the hole...

  • Page 24

    24 24 type “a” maximum opening type “a” minimum opening type “b” & “c” hole(s) at top type “a” type “b” type “c” vent terminal appliance vent outlet vertical vent pipe run use restrictor type port opening set at horizontal through wall with vertical rise top less than 3’ (91 cm) a maximum from 3’ (9...

  • Page 25

    25 25 appliance preparation attaching rear ceramic support see fi gure 29. Fit the rear ceramic support to the fi rebox back panel with three screws. Attaching appliance to the framing see fi gure 30. Place the heater in position in the framing. Secure the side support angles to the side studding th...

  • Page 26: & Vapor Barriers

    26 26 installations with horizontal termination—installing to wall see location section for full range of horizontal termination applications. Flat on wall installation with valor #551dvk terminal cut the vent terminal pipe unit to size. See fi gure 31. Important! The drain hole must be clearly outs...

  • Page 27

    27 27 13” 12-1/4” 10” 10” drain hole installations with horizontal termination—installing to wall wall opening where applicable, fi t all the required pipes and elbows up to the wall. See the manufacturer’s instructions supplied with the venting sections. Check the wall opening position. Make wall o...

  • Page 28

    28 28 2 - 3” liners ‘h’ horizontal overhang vertical wall termination cap storm collar roof flashing plumber’s tape fixed to wall strap wall strap ceiling firestop ceiling support offset elbows min. 18” overhang should not extend beyond vent if within 48” of termination cap min. 24” (unvented soffit...

  • Page 29

    29 29 remote control installation caution! Don’t connect the batteries to the remote control receiver until the wires are connected to the burner control unit, as short circuit could result in destruction of the electrical components. When installing the remote control, please refer to fi gures 37 a...

  • Page 30

    30 30 gas supply installation the gas supply pipe should enter the appliance case through the opening at the rear left side. The supply pipe should be connected to the appliance gas inlet pipe situated at the left side of the control valve. Supply line connection to the inlet pipe is 3/8” npt ( fema...

  • Page 31

    31 31 ceramic fuel bed installation ceramic walls installation locate the ceramic rear wall in the channel at back of the fi rebox and fl at against the back of the fi rebox. See fi gure 41. Locate the sidewalls against the sides of the fi rebox. Make sure that they are behind the raised edges of th...

  • Page 32

    32 32 window refi tting & checking refi t the window with the bottom two bolts. The bolts should be screwed in securely. Refi t the chain to the top right corner of the window. Refi t the top two bolts securing by turning them through 90°. Pull the top of the window forward and release to check that...

  • Page 33

    33 33 front installation #601sfb standard metal front fit the lower louver unit using the hinge studs and hinge spacers as shown in fi gure 51. Fix the two adhesive backed magnet counter plates to the tabs at the fi rebox sides, which line up with the magnets on the lower louver. See fi gure 51. Fit...

  • Page 34

    34 34 operating your fireplace for your safety, this appliance is fi tted with a fl ame supervision device which will shut-off the gas supply if, for any reason, the pilot fl ame goes out. This device incorporates a fi xed probe, which senses the heat from the pilot fl ame. If the probe is cool, the...

  • Page 35

    35 35 thermocouple probe must be in flame checks a periodic check of the pilot and burner fl ames should be made. Check after the fi re has been on for at least 30 minutes. The pilot fl ame must cover the tip of the thermocouple probe. The main burner fl ame pattern will vary from appliance to appli...

  • Page 36

    36 36 owner’s information setting the time the fi rst thing to do is to set the time. With your thumb, hold down both the auto and timer buttons until f fl ashes. Let go. Note the digital clock on the bottom right hand corner. The ▲ button sets the hour; the ▼button sets the minutes. Set the time. N...

  • Page 37

    37 37 owner’s information setting the fl ame use this setting when you want a particular fl ame level. For instance, you want to watch fl ames burn at their highest level and you don’t mind if the room is too hot. To raise the fl ame, press and hold the ▲ button until the flame gets to the desired l...

  • Page 38

    38 38 lighting instructions thermocouple probe must be in flame lighting instructions to turn off gas to appliance for your safety read before lighting warning: if you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. ...

  • Page 39

    39 39 approved alternative direct vent suppliers for valor models 530, 534, 535, and miles fireplaces’ models mf28 venting parts description venting parts code / availability by manufacturer simpson dura-vent selkirk secure vent rlh industries miles industries te rmination caps horizontal co-axial k...

  • Page 40

    40 40 venting parts description venting parts code / availability by manufacturer simpson dura-vent selkirk secure vent rlh industries miles industries dv 45° elbows galvanized 945 — — — — — black 945b — — sv4ebr45 galvanized swivel 945g 4dt-el45 — sv4e45 — — black swivel 945bg 4dt-el45(b) sv4eb45 d...

  • Page 41: Lor

    41 41 warranty 1. Extended warranty coverage for a period of up to ten (10) years, miles industries ltd., (the “company”) or its appointed distributor will at its option pay the initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in...