Valor 922ECN Installation And Owner's Manual - page 4
4 of 19
539 Windsor Arch w/ Plate
2. OPTIONS
# 975 ZCK Zero Clearance Kit – for installation into combustible type framing.
# 976 BRK Bedroom kit: Includes optional thermostat hand set and wiring harness (for use in Canada only)
# 923 ACF Adorn Cast Front
# 539 or 549 Windsor Cast Arch front. (also requires #540WDK Wire Dress Guard)
# 3336 Closure Plate. For insert installations to cover up to 33” high x 36” wide
3. GENERAL DATA
This appliance is certified for use in Canada and the USA under the following standards :
ANSI Z21.50 – 2000 / CSA 2.22 –2000 , Vented Gas Fireplaces
Can/CGA 2.17 – M91 Gas Fired Appliances for use at High Altitudes.
This appliance must be installed in accordance with local codes, if any, or in the absence of local codes follow the National Fuel
Gas Code ANSI Z223.1 or Canadian Installation Code CAN-1-B149. Only qualified licensed or trained personnel should
install the appliance.
3.1 Venting
This appliance must be connected to an approved venting system.
3.2 Ratings
3.3 Choice of Cast Iron Front Trims
Note : the 539/549 Fronts require a 540 WDK Wire Dress Guard with the 922 heater.
Cast Iron Tolerances – Due to the nature of Cast Iron, dimensional consistency may vary from one unit to the next and
some variation in surface finish and flatness is to be expected. We have done our best to control and make allowance,
however some variation is inevitable.
Closure plates may be required for insert applications where cast fronts do not cover entire openings.
Standard black 33” high x 36” wide closure plate with black aluminum extrusion edge is available.
922ECN
922ECP
Altitude (Ft)
0-4500
Input Max. (Btu/h)
20,500
19,000
Input Min (Btu/h)
12,000
12,500
Manifold pressure (in w.c.)
3.7
10.5
Max Supply pressure (in w.c)
10.5
13
Min. Supply pressure (in. w.c.)
5
11
923 Adorn
549 Windsor Arch w/o Plate