Vectaire ELEGANCE EL1003DT Installation And Operating Instructions Manual - page 3
WARNING: Damage could be caused to the product
if the installation instructions are not followed
• The product should not be used in an ambient
temperature higher than 40°C (104°F).
• The product should not be exposed to atmos-
pheric agents (rain, sun, snow, etc.).
• The product or its parts should not be placed in
water or other liquids.
• Routine maintenance as described below should
be carried out to check the condition of the fan.
• The air or fumes being extracted must be clean
and free from greasy particles, soot, chemical and
corrosive agents, flammable or explosive mixtures.
• The product must be installed by professionally
qualified personnel. Incorrect installation can
cause damage to people, animals or property,
for which the manufacturer cannot be held
liable.
• The product must be connected to the electricity
supply via a double pole switch of a suitable size,
with contact openings of at least 3 mm.
• If the electrical supply board (or switching device)
is located some distance from the fan a means of
local isolation must be provided.
• To ensure optimum operation, do not block the
air intake and exit vents.
• Any ducting used must be free of blockages, and
should be insulated if in an unheated area.
• The room where the product is operating must
have adequate air replacement to ensure max
mum effectiveness.
• If the product is sited in a room containing a
fuel burning appliance which is not of the bal-
anced flue type, the installer must ensure that
air replacement is adequate both for the fan
and the fuel burning appliance (UNI CIG
7129).
• The product must not be used as an activator
for water heaters, stoves, etc.
• The product must not exhaust into ducts
designed to evacuate fumes from combustion
in stoves or other combustion-powered
devices.
RANGE
Trickle Speed 1- 8 lt/sec - 28.8 m³/h
Trickle Speed 2 - 13 lt/sec - 46.8 m³/h
EL1003 - this fan combines the latest technology
with energy saving and efficiency. It is a quiet run-
ning, 3 speed fan. It is designed to run continuously
at a pre-selectable choice of 2 trickle speeds (fixed at
installation). The user can boost the fan speed to its
maximum performance when required by means of
the cord or remove the cord and use a remote
switch, light switch, PIR sensor or humidistat. The
EL1003 is SAP Appendix Q Listed
EL1003LV - SELV, 12v version EL1003.
EL1003DT - 3 speed, continuous running fan with
delay-on timer and pull cord. The delay-on timer ver-
sion will run at low speed until the boost speed is
activated by means of the cord or, if the cord is
removed, by means of a remote switch, light switch,
PIR sensor or humidistat. There is a 2 minute delay
before the fan starts to run at its high speed - if the
boost speed is deactivated before that time lapse,
the fan will continue to run at low speed. If the boost
speed is activated, the fan will operate at high speed
until the boost switch is turned off. After this, the fan
will continue at high speed for the length of time set
on the timer overrun adjustment, between 0 and 30
mins. (See page 8). After the overrun time has
elapsed, the fan will return to the slower speed.
EL1003DTLV - SELV, 12v version of EL1003DT
EL1003HDT - 3 speed, continuous running fan. The
fan runs continuously at the pre-selected lower
speed, and the boost (speed 2) will start to operate
automatically when the relative humidity (adjustable
between 40% and 90% +/-5% tolerance) reaches
the pre-set level and will continue to operate at this
speed until the humidity has been dispersed and the