Velleman AVM360 Operation Manual

Other manuals for AVM360: User Manual
Manual is about: ANALOGUE MULTIMETER

Summary of AVM360

  • Page 1

    Avm360 analog multimeter operation manual gebruikershandleiding manuel d’utilisateur.

  • Page 2

    Avm360 gb 1 avm360 analogue multimeter 1. Description your avm360 is a professional analogue multimeter. It is ideally suited for field, lab, shop, and home applications. It is capable of performing functions : dc voltage ac voltage dc current resistance transistor iceo test transistor hfe test diod...

  • Page 3

    Avm360 gb 2 your avm360 is an example of superior design and craftsmanship. The following suggestions will help you care for the multimeter so you can enjoy it for years : l keep the multimeter dry. If it gets wet, wipe it dry immediately. L use and store the multimeter only in normal temperature en...

  • Page 4

    Avm360 gb 3 indicator zero corrector ô range selector switch knob í measuring terminal + ÷ measuring terminal - com (common) û output (series condenser) terminal ø 0 Ω adjusting knob ù panel î indicator pointer ü rear case bolt ê rear case 3. Reference table for reading.

  • Page 5

    Avm360 gb 4 test range position scale to read multiplier dc 0.1v b 10 x 0.01 0.5v b 50 x 0.01 2.5v b 250 x 0.01 dc volt 10v b 10 x 1 50v b 50 x 1 250v b 250 x 1 1000v b 10 x 100 ac 10v c 10 x 1 ac 50v b 50 x 1 volt 250v b 250 x 1 1000v b 10 x 100 dc 50 µa b 50 x 1 dc 2.5 ma b 250 x 0.01 current 25 m...

  • Page 6

    Avm360 gb 5 4. Operating instructions 4.1 Ω test 1. Plug the test leads into com and + sockets. 2. Place the range selector to a prescribed range position. 3. Short the test leads and turn 0 Ω adj to set the pointer to zero position. 4. Make sure that there is no voltage across the circuit to be tes...

  • Page 7

    Avm360 gb 6 1. Plug the test leads into + and - com sockets. 2. Set the range selector to x10 (15ma) for small size transistor, or to x1 (150ma) for big size transistor. 3. Adjust 0 Ω adj to set the pointer to zero position of the Ω scale. 4. Connect the transistor with the tester : for npn transist...

  • Page 8

    Avm360 gb 7 4.8 diode test 1. Set the range selector at selected range position : x 1k for 0 - 150 µa test, x 100 for 0 - 1.5 ma test, x 10 for 0 - 15 ma test, x 1 for 0 - 150 ma test. 2. Connect the diode to the tester. For i f (forward current) test, connect the "n" terminal of the tester to the p...

  • Page 9

    Avm360 gb 8 5.4 resistance ranges : x 1 - 0.2 Ω up to 2 k Ω , midscale, at 20 Ω x 10 - 2 Ω up to 20 k Ω , midscale, at 200 Ω x 100 - 20 Ω up to 200 k Ω , midscale, at 2 k Ω x 1k - 200 Ω up to 2 m Ω , midscale, at 20 k Ω x 10k - 2 k Ω up to 20 m Ω , midscale, at 200 k Ω accuracy at fsd : 3 5.5 genera...