Velleman DK-9350 User Manual

Manual is about: DUAL OUTPUT FULL FEATURE VANDAL-RESISTANT KEYPAD

Summary of DK-9350

  • Page 1

    Haa9350 dual output full feature vandal-resistant keypad (dk-9350) user manual 2.

  • Page 2

    Table of contents introduction assembly description of connection terminals & indicators connec on terminals the led indicators back ligh ng the pacifier tones & the led indica ng signals standard programming summary chart setting & programming criteria for programming enter and exiy programming mode...

  • Page 3

    Introduction assembly dk-9350 and dk-9380 are dual relay output, vandal resistant weatherproof keypads. They employ durable back-lit metal bu on keyboard and rugged metal housing ideally for high traffic and harsh environment applica ons. The output 1 is a form c relay with 5 amp contact ra ng mainly ...

  • Page 4

    Description of connection terminals & indicators 1 - 2 : 12-24v ac/dc -- power input connect to 12-24v ac or dc power supply. The (–) supply, terminal (2) and (–) gnd terminal (12) are the common grounding points of the keypad system. No selec on jumper is required for the full input voltage range. ...

  • Page 5

    9 - eg in -- egress input a normally open (n.O.) input terminal refers to (–) ground, with the help of a normally open bu on to ac vate the output 1 for the same me period as like the user code. Egress bu on is usually put inside the house near the door. More than one egress bu ons can be connected...

  • Page 6

    14 : o/p 1 inhib. -- output 1 inhibit a normally open (n.O.) input terminal refers to (–) ground. Both user code 1 and egress bu on can not ac vate output 1 while this terminal is ed to (–) ground. It is prepared for cross wire connec on in inter-lock applica on. 15 : int. Lock -- inter-lock contro...

  • Page 7

    The led indicators mains (amber) this is a status indicator. It flashes during standby and other indica ons in synchroniza on with the pacifier tones. See the chart of led indica on signals below for the details. Door (green & red) this is a dual led at the right side of the panel. It lights up in gre...

  • Page 8

    A) enter programming mode with master code (exit-factory master code: 0 0 0 0) entry of master code confirm comments set system to programming mode note: factory has put a master code into the keypad before exit-factory, owner may take it for first me use. B) system refreshing – installer programming...

  • Page 9

    D) configura on of output modes – installer programming (default: momentary, 1-second for all 3 outputs) loca on code of timing confirm comments 1 to 999 loca on code of timing confirm comments 1 to 999 output 2, momentary mode from 1 to 999 seconds (default = 1 second) output 2, start / stop mode (tog...

  • Page 10

    H) user code entry modes (auto or manual) – installer programming (default: manual) loca on func on codes confirm comments i) pacifier tones (key-press beeps) – installer programming (default: on) loca on func on codes confirm comments pacifier tone off, good for silent environment pacifier tone on for e...

  • Page 11

    Criteria for programming (1) the keypad must be in programming mode for making se ng and data changes. (2) programming can be accomplished in workshop or at the installa on site. All data are stored in a non-vola le memory and will not be lost in power off. (3) do not disconnect the keypad from power...

  • Page 12

    Loca on new master code confirm note: ● loca on is the storage loca on for the master code. ● the master codes can be 4-8 digits long. ● user codes must have the same length as the master code if the keypad is in auto code entry mode. Programming example : 1. Set keypad to programming mode with maste...

  • Page 13

    Two groups of user codes can be programmed to operate output 1 and 2 respec vely. The following are the programming procedures. Loca ons user id entry of code confirm output 1 00 - 99 4 -8 digits output 2 0 - 9 4 -8 digits note: ● loca ons 1 and 2 are the storage places for the user codes for output ...

  • Page 14

    Super user code is a mul -task user code for ac va ng the two outputs 1 & 2 and opera ng the special func ons of output 1. Loca ons super user code confirm 4 - 8 digits note: ● the super user code can be 4-8 digits long in manual code entry mode; but must has the same length as the master code if the...

  • Page 15

    2) overriding the door lock controlled by output 1 (keep door un-locked) the output 1 is usually for door lock control. In some circumstances, the door lock may be required to be un-locked for a period for people to enter-exit the premises conveniently without user code. The func on starts / stops i...

  • Page 16

    Duress code(s) is an important code to protect the user in case of forcing to open the door under duress. The duress code operates like a normal user code to ac vate output 1 for door opening and at the same me it also ac vates the duress output without any indica on. The duress output can be used ...

  • Page 17

    Visitor codes are temporary user codes that can be assigned to visitors or temporary workers to ac vate output 1 (usually for door lock actua on). They can be programmed for one-time use or with time-limit in a valid dura on. Loca ons user id valid dura on entry of code confirm 0 - 9 00 or 01 to 99 v...

  • Page 18

    To delete a user who has le the company or who no longer has the authority to enter the protected area. Deleting examples: 1. Set keypad to programming mode with master code and key. Taking the previous programmed master code 3 2 8 9 as example here: 2. Dele ng the codes one by one if more than one...

  • Page 19

    Outputs 1 & 2 can be programmed to trigger with the following op ons. For a programmed length of me from 1 to 999 seconds; or to trigger on and off in toggle with a user code; or to trigger on with an accelerated start code and off with an full digit user code. Loca ons time length confirm a) 1 – 99...

  • Page 20

    Operation : 1. Operate output 1 in momentary mode of 5 seconds using user code 8 3 2 1 that was programmed previously: ----------- output relay 1 operates for 5 seconds 2. Operate output 2 in start / stop mode using user code 5 4 3 2 1 that was programmed previously: -------- output relay 2 start / ...

  • Page 21

    The keypad can be programmed to give system lock up or to report the event in order to secure the premises against unauthorized entry of mul ple false codes are entered. The lock-up op ons are represented by a 1 or 2 digits code for owner’s selec on. Loca ons lock-up op ons confirm 1 to 2 digits prog...

  • Page 22

    Output ac va on announcer (loca on 81) the keypad will give door forced-open warning if the door is opened without using a user code or pressing the egress bu on. This func on requires an op onal normally closed (n.C.) door posi on monitoring switch on the door (usually a magne c contact or other do...

  • Page 23

    Some users like to press key to confirm a code entry manually to prevent the unauthorized person to easily check out the digit length of the user code; but some people do not. They prefer the keypad to check the code automa cally when the last number of digit is reached. The keypad can be programmed ...

  • Page 24

    Most of the keypads mainly controls “going in” with user codes and controls “going out” simply pressing an egress bu on. However, in some situa ons, providing some warning and delay are desirable before the door is open a er pressing the egress bu on. For example, in hospitals or schools, it may be ...

  • Page 25

    Note: for safety and to avoid confusion, when a delay is programmed, please post a no ce near the egress bu on to no fy the users. Here are two example s ckers for an egress bu on with 5 seconds momentary delay or 5 seconds press-and-hold delay. Press the bu on momentarily and wait for 5 seconds un ...

  • Page 26

    A) enter programming mode with master code (exit-factory master code: 0 0 0 0) entry of master code confirm comments set system to programming mode note: factory has put a master code into the keypad before exit-factory, owner may take it for first me use. B) system refreshing to single user mode – i...

  • Page 27

    2) recording super user code – user programming (no default codes) loca on entry of code confirm comments 4 digits fixed owner’s mul -task user code 3) recording duress codes – user programming (no default codes) loca on entry of code confirm comments 4 digits fixed 4) recording the visitor codes – user...

  • Page 28

    ● opera on voltage: 12-24v ac/dc, full voltage range ● opera on current: quiescent - 16ma maximum - 78ma (relays opera ng) ● opera on modes: a) mul user mode -- 100 user codes for output 1 (user number 00-99), auto or manual code entry -- 10 user codes for output 2 (user number 0-9), auto or manual...

  • Page 29

    1) basic wirings of a stand alone door lock note: connect the 1n4004 as close as possible to the lock in parallel with the lock power terminals to absorb the back emf to prevent it from damaging of the keypad. To avoid electro-sta c-discharge from interfering with the opera on of the keypad, always ...

  • Page 30

    2) basic wirings for door lock open and alarm arm-disarm control note: the door lock function is exactly the same as like the application example (1) relay output 2 is used for alarm arm-disarm control. Please consult your alarm control panel manual for the appropriate output contact and the operati...

  • Page 31

    3) basic wirings of an inter-lock system using two keypads an inter-lock system needs two door controllers. This application example uses two keypads with simple cross wire connection on their "output 1 inhibit" and "inter-lock control output" terminals. It is necessary to link up the "(–) gnd" term...

  • Page 32

    Application hints for the auxiliary facilities the tamper switch is nomally closed while the keypad is secured on gang box. It is open when the keypad is removed from the gang box. To prevent sabotage, connect these terminals in series with a 24 hour n.C. Protection zone of an alarm system if requir...

  • Page 33

    The duress output will switch to (−) ground when duress code is entered. You may use it to turn on an led lamp and / or a small buzzer to notify a guard; or connect it to a 24 hour normally open protection zone of an alarm system. Only one connection option is recommended. Make sure that the sink cu...

  • Page 34

    The door bell terminal is a normally open relay contact with the power rating of 30vdc/1a. It is prepared for triggering of a door chime. (g) door bell door bell n.O. Electronic door chime door bell button (f) door bell the door bell terminal is a normally open relay contact with the power rating of...

  • Page 35

    Dry contact a dry contact means that no electricity is connected to it. It is prepared for free connec ons. The relay output contacts provided in this keypad system are dry contacts. N.C. Normally closed, the contact is closed circuit at normal status. It is open circuit when ac ve. N.O. Normally op...

  • Page 36

    Velleman® service and quality warranty since its foundation in 1972, velleman® acquired extensive experience in the electronics world and currently distributes its products in over 85 countries. All our products fulfil strict quality requirements and legal stipulations in the eu. In order to ensure ...