Audible notifications
During operation, following audible signals will be generated by the master control unit.
Event
Notification
System in Exit Delay Period
OR
System in Entry Delay Period
Exit And Entry Beeps
• Short beeps at 0.5 second interval
• Increase to 4 beeps/second at the last 10 seconds, then
•
One long beep to indicate the end of the delay period
System in Standby Mode Period
• Short beeps at 0.5 second interval
• Increase to 4 beeps/second at the last 10 seconds, then
•
One long beep to indicate the end of the period
Note: beep halts when programming mode or battery test is
started.
System is or was in Alarm condition
(Alarm occurred)
Warning beeps
•
4 fast beeps at 1 second interval
Successful Keypad operation
OR
Battery is Normal after Testing
•
2 Short beeps
AC power Failure
•
1 Short beep/30 seconds
Battery Low After Testing
• 5 Short beeps first, then
• 1 Short beep/30 seconds
Opening the cabinet
The HAM263D master control unit is protected from opening by a built-in tamper switch. Opening
the cabinet door will trigger the alarm.
• Before opening the cabinet, put the system in stand-by mode. To do this, disarm the system via
the keypad. Refer to the section on the keypad for the procedure.
• Specifications
power supply
16.5V, 3A
back-up battery requirements
7Ah, 12V, rechargeable sealed lead acid battery (not included,
e.g. WP7-12)
standby current
typically 100mA
temperature range
0°C~+65°C
entry delay
15~90s
exit delay
60s
alarm duration
3~15min or infinite
power up delay (standby mode)
60s
dimensions master unit
270 x 265 x 78mm
dimensions keypad
117 x 117 x 27mm
dimensions box
346 x 540 x 152mm
weight (master unit + keypad)
2,5kg