Velux KLI 110 Instructions Manual - page 7
12 VELUX
VELUX 13
3-4 sec
2
3
2
3
1
prg
prg
max
5 sec
4
5
max 2 sec
max 2 sec
Configuring control keypad KLI 110 in addition to existing control
keypad KLI 110
1
Disconnect all products that are not to be controlled by control
keypad KLI 110 from control unit KLC 500.
2
Transmit system from existing keypad by pressing the PRG button for
3-4 seconds. LED flashes green slowly.
3
Press PRG button on additional control keypad KLI 110 for
max 2 seconds to receive system from existing keypad in the new
keypad. Reception can take up to 2 minutes. LED flashes green
slowly.
4
Remove cover from control unit. When LED in additional keypad
flashes green quickly, press test button in control unit for
max 5 seconds to receive system from keypad in the control unit and
to transmit functions of control unit.
5
When the first electrical product runs briefly back and forth, config-
ure the product(s) in the additional keypad by pressing any operation
key for max 2 seconds. LED flashes green slowly for a few seconds.
When configuration has been completed, LED is green for 4 seconds.
If configuration has failed, LED is red for 4 seconds.
note: For configuration of control keypad KLI 110 in addition to exist-
ing interface KLF 100, please refer to instructions provided with the
interface.
5