removing/adding electrical products connected to control unit
KLC 500 from/to control keypad KLI 110
1
Disconnect all electrical products and reconnect only products to be
removed from/added to control keypad KLI 110.
Complete item 2 within 10 minutes from reconnection.
2
Remove/add control and transmit functions by pressing PRG button
in keypad for max 2 seconds. This procedure can take up to 2 min-
utes. LED flashes green slowly.
3
Remove cover from control unit. When LED in keypad flashes green
quickly, press test button in control unit for max 5 seconds to receive
system in the control unit and to transmit function from control unit.
4
When the first electrical product runs briefly back and forth, config-
ure the product(s) in the keypad by pressing any operation key for
max 2 seconds. LED flashes green slowly for a few seconds.
The product can now be controlled by control keypad KLI 110.
When configuration has been completed, LED is green for four seconds.
If configuration has failed, LED is red for four seconds.
note: For electrical products controlled by a remote control KLR 100,
please refer to the user manual for KLR 100.