  • Page 1

    Cpm series hb0078 installation instructions intended for domestic cooking only installer: leave this manual with homeowner. Homeowner: use and care information on pages 12 and 13. Read and save these instructions venmar ventilation inc., 550 lemire blvd. Drummondville qc j2c 7w9 1-800-567-3855 regis...

  • Page 2: Warning

    2 to reduce the risk of fire, electric shock or injury to persons, observe the following: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit,...

  • Page 3

    3 hl0107 - cpm1 and cpm2 power pack systems - m odel 634 or 644 (r oof cap ) m odel 643 (8” r ound wall cap ) m odel 418 (10” r ound adjustable elbow ) m odel 410 (10” r ound duct — 2 ft . Sections ) 10” r ound vertical in - line damper ( supplied with dual blower power packs ) m odel 437 (h igh cap...

  • Page 4: 1. Prepare

    4 1. Prepare installation plan where and how the ductwork will be installed. Access to the top of the hood is preferred for connection of ductwork. Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If installing cpm1 power pack, use 8” round ductwo...

  • Page 5: ’

    5 3. Custom hood preparation ( cont ’ d ) to minimize the gap around the power pack, take actual width and depth measurements of power pack and add 1/16” to get d and e measurements. Cut the hole in the bottom of the cabinet according to dimensions. See chart and illustration for details. 4. Mount c...

  • Page 6: 7.  Remove Bottom Panel

    6 6. Remove grease drip rail a. Lift grease drip rail to disengage it from the bottom panel. B. Slide grease rail all the way to the left or right ( ) and lift the opposite end to disengage the other end from the bottom panel ( ). Remove it from the power pack and set aside for later use. 7. Remove ...

  • Page 7: 11. Connect Wiring

    7 10. Install adapter and damper (cpm2 models only) using 2 no. 8 x 3/8” screws from parts bag, assemble the adapter on the top of the power pack. Seal all joints with metal foil duct tape to eliminate air leaks. Install 10” damper inside the vertical ductwork that will be attached to power pack. Do...

  • Page 8: 12. Remove  Blower(S)

    8 12. Remove blower(s) in order to ease the power pack alignment with existing ductwork, unplug and disassemble the blower(s) from the power pack before installing the custom hood. For each blower, using a 5/16” socket, remove all blower mounting screws from the inner top of the power pack front and...

  • Page 9: 13. Install Power Pack

    9 13. Install power pack caution take care not to kink ducting when installing the power pack. Using provided no. 8 x 1/2” chrome plated screws, install the power pack inside the custom hood. Start with 2 screws on front corners, then use 4 screws for sides and use the remaining ones to finalize sec...

  • Page 10: 14. Reinstall Blower(S) (

    10 14. Reinstall blower(s) ( cont ’ d ) plug the blower(s) in. He0085 a ll models 15. Reinstall bottom panel lift the bottom panel and engage the power pack metal tabs in bottom panel slots, as shown in details a and b below. Secure the bottom panel to the power pack using its screws previously remo...

  • Page 11: 18. Light  Bulbs

    11 17. Reinstall baffle filters caution remove protective plastic film covering filters before installing them. It is recommended to install side filters first and finish with center one(s). Insert one end of the filter into the upper channel of the power pack. Raise the other end toward the inside ...

  • Page 12: 19. Use And  Care

    12 19. Use and care baffle filters the baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease — like frying foods or wok cooking. Remove baffle filters by pushing them towards the back of hood and rotating filters do...

  • Page 13: 20. Operation

    13 20. Operation always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter. Hc0038 1 2 3 hc0056 0 1 2 1 2 4 3 a b 1) h aloge...

  • Page 14: 21. Wiring Diagram

    14 21. Wiring diagram b l k b l ac k blu blue brn brown gry grey org orange red red wht white yel yellow color code line ground neutral 120 vac fan switch blk gry red red wht thermostat main switch blk blk gry blk lamp switch l3 2 lamp lamp wht wht wht wht yel yel 9408 a b 1 2 3 4 blu wht ora blk wh...

  • Page 15: 22. Warranty

    15 22. Warranty venmar ventilation five-year warranty venmar ventilation inc. Warrants to the original consumer purchaser of the venmar connaisseur cpm series range hood that such product will be free from defects in materials or workmanship for a period of five (5) years from date of original purch...

  • Page 16: 23. Service  Parts

    16 23. Service parts venmar connaisseur cpm1 & cpm2 series hl0168 r eplacement p arts and r epairs in order to ensure your unit remains in good working condition, you must use venmar ventilation inc. Genuine replacement parts only. Venmar ventilation inc. Genuine replacement parts are specially desi...