Vent-a-Hood EUROLINE Installation Instructions Manual - Ducting Do’S and Don’Ts
Page 2
L113 0808A
Ducting Do’s and Don’ts
NEVER restrict the duct size. The island dual blower unit (T200) requires 8” round duct or
equivalent (50 square inches). The island cluster blower unit (T400) requires 12” round or
equivalent (113 square inches). Using the included Vent-A-Hood transition will ensure proper
efficiency.
Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce
performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special
duct requirements and placement of duct against combustibles. Make the duct run as short
and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead,
use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs
over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree
elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers (back page) will
ensure proper efficiency. Airflow must not be restricted at the end of the duct run. Do not use
screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into
an attic or chimney. Where possible, seal joints with duct tape. The hood must be ducted to the
outdoors without restrictions.
Blower
Duct Size
Sq. Inch Area Vent-A-Hood Transition
Island Dual (T200)
8” round or equivalent
50”
VP565 (Included)
Island Cluster Blower (T400)
12” round or equivalent
113”
VP564 (Included)
YES
NO
Smooth Duct
Smooth Gradual Turn
Flexible Duct
Sharp Angled Turns